High precision measurement of intensity peak shifts in tunable cascaded microring intensity sensors

Not Accessible

Your library or personal account may give you access

Abstract

We demonstrate a method to precisely track intensity peak shifts in tunable cascaded double-microring based refractive index sensors. Without modifications, width of the intensity peak of a tunable cascaded microring device limits the precision of peak-shift measurements and thereby the limit of detection of the sensor. We overcome this limitation by using dual harmonic lock-in detection for precisely determining the position of the intensity maximum. Using this modification, we have demonstrated a reduction in the full width at half-maximum (FWHM) of the intensity peak by a factor of over 1300. We show that such a reduction in FWHM of the peak curve can significantly improve the detection limit of a tunable cascaded microring-based sensor.

© 2016 Optical Society of America

Full Article  |  PDF Article
More Like This
Temperature-insensitive optical sensors based on two cascaded identical microring resonators

Guoshuai Su, Mingyu Li, Zhiping Yang, Jiayi Xie, Yuxia Song, and Jian-Jun He
Opt. Lett. 47(17) 4327-4330 (2022)

Broadband tunable microwave photonic phase shifter with low RF power variation in a high-Q AlN microring

Xianwen Liu, Changzheng Sun, Bing Xiong, Jian Wang, Lai Wang, Yanjun Han, Zhibiao Hao, Hongtao Li, Yi Luo, Jianchang Yan, Tong bo Wei, Yun Zhang, and Junxi Wang
Opt. Lett. 41(15) 3599-3602 (2016)

High precision dual-modulation differential terahertz ATR sensor for liquid measurements

Xiujun Zheng, Thomas Gevart, and Guilhem Gallot
Opt. Lett. 46(16) 4045-4048 (2021)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (6)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (8)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.