Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system

Not Accessible

Your library or personal account may give you access

Abstract

In a circular scanning photoacoustic computed tomography (PAT/PACT) system, a single-element ultrasound transducer (SUT) (rotates in full 360° around the sample) or a full-ring array transducer is used to acquire the photoacoustic (PA) data from the target object. SUT takes several minutes to acquire the PA data, whereas the full-ring array transducer takes only few seconds. Hence, for real-time imaging, full-ring circular array transducers are preferred. However, these are custom built, very expensive, and not available readily on the market, whereas SUTs are cheap and easily available. Thus, PACT systems can be made cost effective by using SUTs. To improve the data acquisition speed, multiple SUTs can be employed at the same time. This will reduce the acquisition time by N-fold if N numbers of SUTs are used, each rotating 360/N degrees. Experimentally, all SUTs cannot be placed exactly at the same distance from the scanning center. Hence, the acquired PA data from each transducer need to be reconstructed with their corresponding radii in a delay-and-sum reconstruction algorithm. This requires the exact location of each SUT from the scanning center. Here, we propose a calibration method to find out the distance from the scanning center at which each SUT acquires the PA data. Three numerical phantoms were used to show the efficacy of the proposed method, and later it was validated with experimental data (point source phantom).

© 2018 Optical Society of America

Full Article  |  PDF Article
More Like This
Co-optimization method to improve lateral resolution in photoacoustic computed tomography

Yang Zhang, Shufan Yang, Zhiying Xia, Ruijie Hou, Bin Xu, Lianping Hou, John H. Marsh, Jamie Jiangmin Hou, Seyed Mojtaba Rezaei Sani, Xuefeng Liu, and Jichuan Xiong
Biomed. Opt. Express 13(9) 4621-4636 (2022)

Impact of sensor apodization on the tangential resolution in photoacoustic tomography

Pankaj Warbal, Manojit Pramanik, and Ratan K. Saha
J. Opt. Soc. Am. A 36(2) 245-252 (2019)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (6)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (4)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.