Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 68,
  • Issue 4,
  • pp. 466-474
  • (2014)

Immunoglobulin G Measurement in Blood Plasma Using Infrared Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

A rapid, simple, and inexpensive method to measure the immunoglobulin G (IgG) concentrations in blood samples in human and veterinary medicine is highly desired. Infrared spectroscopy (coupled with chemometric manipulation of spectral data) has the advantages of simple sample preparation, rapid implementation of analysis, and low cost. Here a method that exploits infrared spectroscopy as the basis to measure IgG concentration in animal plasma samples is reported, with radial immunodiffusion (RID) used as the reference test method for partial least squares (PLS) calibration model development. Smoothed non-derivative and the second-order derivative spectra were used to develop calibration models. Various additional spectral preprocessing steps were evaluated to optimize the calibration models, and the possible benefits of using an internal standard (potassium thiocyanate [KSCN]) were investigated. Monte Carlo cross-validation was used to determine the optimal number of PLS factors, and an independent prediction set was used to test the predictive performances of provisional models. The effects of various preprocessing options (spectral smoothing, derivation, normalization, region selection, mean-centering, and standard deviation scaling) on quantification accuracy were investigated. The root mean squared error of prediction (RMSEP) for different combinations of spectra preprocessing steps was 394 ± 36 mg/dL for the non-derivative spectra and 427 ± 101 mg/dL for the second-order derivative spectra. Immunoglobulin G concentrations produced by the optimized PLS model for the non-derivative spectra (RMSEP = 352 mg/dL) were found to be stable with respect to different splits of the samples among the calibration, validation, and prediction sets. The precision of the Fourier transform infrared (FT-IR) method is found to be slightly superior to that of the RID method. The results of this work indicate that infrared spectroscopy is a promising technique for economically and rapidly determining the IgG concentrations of plasma and plasma-derived samples.

PDF Article
More Like This
Label-free multiplex sensing from buffer and immunoglobulin G sensing from whole blood with photonic crystal slabs using angle-tuning of an optical interference filter

Fabio A. Kraft, Holger Baur, Moritz Bommer, Andreas Latz, Stefanie Fitschen-Oestern, Sabine Fuchs, and Martina Gerken
Biomed. Opt. Express 14(5) 2293-2310 (2023)

Multicomponent blood analysis by near-infrared Raman spectroscopy

Andrew J. Berger, Tae-Woong Koo, Irving Itzkan, Gary Horowitz, and Michael S. Feld
Appl. Opt. 38(13) 2916-2926 (1999)

Determination of glucose in whole blood samples by mid-infrared spectroscopy

Yoen-Joo Kim, Sangjoon Hahn, and Gilwon Yoon
Appl. Opt. 42(4) 745-749 (2003)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.