Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 67,
  • Issue 9,
  • pp. 1019-1028
  • (2013)

Continuous Online Fourier Transform Infrared (FT-IR) Spectrometry Analysis of Hydrogen Chloride (HCl), Carbon Dioxide (CO2), and Water (H2O) in Nitrogen-Rich and Ethylene-Rich Streams

Not Accessible

Your library or personal account may give you access

Abstract

The prevalence of optical spectroscopy techniques being applied to the online analysis of continuous processes has increased in the past couple of decades. The ability to continuously “watch” changing stream compositions as operating conditions change has proven invaluable to pilot and world-scale manufacturing in the chemical and petrochemical industries. Presented here is an application requiring continuous monitoring of parts per million (ppm) by weight levels of hydrogen chloride (HCl), water (H<sub>2</sub>O), and carbon dioxide (CO<sub>2</sub>) in two gas-phase streams, one nitrogen-rich and one ethylene-rich. Because ethylene has strong mid-infrared (IR) absorption, building an IR method capable of quantifying HCl, H<sub>2</sub>O, and CO<sub>2</sub> posed some challenges. A long-path (5.11m) Fourier transform infrared (FT-IR) spectrometer was used in the mid-infrared region between 1800 and 5000 cm<sup>?1</sup>, with a 1 cm<sup>?1</sup> resolution and a 10 s spectral update time. Sample cell temperature and pressure were controlled and measured to minimize measurement variability. Models using a modified classical least squares method were developed and validated first in the laboratory and then using the process stream. Analytical models and process sampling conditions were adjusted to minimize interference of ethylene in the ethylene-rich stream. The predictive capabilities of the measurements were ±0.5 ppm for CO<sub>2</sub> in either stream; ±1.1 and ±1.3 ppm for H<sub>2</sub>O in the nitrogen-rich and ethylene-rich streams, respectively; and ±1.0 and ±2.4 ppm for HCl in the nitrogen-rich and ethylene-rich streams, respectively. Continuous operation of the instrument in the process stream was demonstrated using an automated stream switching sample system set to 10 min intervals. Response time for all components of interest was sufficient to acquire representative stream composition data. This setup provides useful insight into the process for troubleshooting and optimizing plant operating conditions.

PDF Article
More Like This
Open-path anti-pollution multi-pass cell-based TDLAS sensor for the online measurement of atmospheric H2O and CO2 fluxes

Mingsi Gu, Jiajin Chen, Jiaoxu Mei, Tu Tan, Guishi Wang, Kun Liu, Gang Liu, and Xiaoming Gao
Opt. Express 30(24) 43961-43972 (2022)

Absorption of Infrared Radiation by CO2 and H2O. Experimental Techniques*

Darrell E. Burch, David A. Gryvnak, and Richard R. Patty
J. Opt. Soc. Am. 57(7) 885-895 (1967)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.