Abstract
The liquid fuel that accumulates in the engine manifold and cylinders during cold start conditions is thought to contribute significantly to excess hydrocarbon emissions. Two fluorescent dopants, cyclohexanone and 2-methyl-cyclopentanone, have been tested for use as fluorescent markers for quantitative two-dimensional (2D) imaging of the thickness of automotive fuel films in the range 0-1 mm. These dopants are co-evaporative with synthetic automotive fuel and have fluorescence that is virtually independent of oxygen concentration equivalent to saturation under 5 atm air at temperatures of 20-200 C. Selection, calibration procedures, and (nonengine) demonstration laser-induced-fluorescence (LIF) imaging experiments are discussed. Index Headings: Fluorescence; Diagnostics; Engines; Liquid films; Cold start.
PDF Article
More Like This
Cited By
You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator