Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 52,
  • Issue 9,
  • pp. 1203-1209
  • (1998)

Effect of Wavelength Drift on Single- and Multi-Instrument Calibration Using Genetic Regression

Not Accessible

Your library or personal account may give you access

Abstract

The ability of genetic regression (GR) to correct for wavelength drift in instrument responses was investigated in single- and multi-instrument calibrations. Sample spectra of ternary mixtures were collected on two near-infrared (NIR) spectrometers, one a dispersive instrument and one a Fourier transform instrument, with different resolutions. In the first and second cases, calibration models were generated with the use of spectra collected on a single instrument. For the third case, hybrid calibration models (HCMs) were built in order to combine spectra from two instruments into one calibration model. In order to simulate a wavelength shift, some of the spectra were shifted along the wavelength axis from 0 nm to 6 nm. The performance of GR was poor when calibration models produced from unshifted spectra were used to predict shifted spectra. However, the inclusion of shifted spectra in the calibration model corrected the prediction of shifted and unshifted spectra at levels similar to those of models built and evaluated by using only unshifted spectra.

PDF Article
More Like This
Effect of different regression algorithms on the estimating leaf parameters based on selected characteristic wavelengths by using the PROSPECT model

Yangyang Zhang, Jian Yang, Xiuguo Liu, Lin Du, Shuo Shi, Jia Sun, and Biwu Chen
Appl. Opt. 58(36) 9904-9913 (2019)

Use of the optogalvanic effect and the uranium atlas for wavelength calibration of pulsed lasers

Norman J. Dovichi, David S. Moore, and Richard A. Keller
Appl. Opt. 21(8) 1468-1473 (1982)

Long-term analysis of GOME in-flight calibration parameters and instrument degradation

Melanie Coldewey-Egbers, Sander Slijkhuis, Bernd Aberle, and Diego Loyola
Appl. Opt. 47(26) 4749-4761 (2008)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.