Abstract
Ultrafast laser pump-XAFS probe spectra of ironhexacyanide solvated in water have been measured using a laser-driven plasma x-ray source. A new x-ray source driven by a 15-W, 5- kHz laser system has been developed.
© 2006 Optical Society of America
PDF ArticleMore Like This
Xiaodi Li, Brian Ahr, Christopher M. Laperle, Taewoo Lee, Christian Reich, and Christoph G. Rose-Petruck
LTuA2 Laser Science (LS) 2007
Nils Huse, Hana Cho, Tae Kyu Kim, Lindsey Jamula, James K. McCusker, Frank M. F. de Groot, and Robert W. Schoenlein
TuD2 International Conference on Ultrafast Phenomena (UP) 2010
Yan Jiang, Wei Li, Guohua Cao, Taewoo Lee, Gyanprakash Ketwaroo, and Christoph G. Rose-Petruck
TuD3 Applications of High Field and Short Wavelength Sources (HFSW) 2001