Abstract

The design, fabrication, and characterization of world’s first Fabry-Perot diaphragm fiber-optic sensor (DFOS) are reported. A critical test is proposed to discriminate a pure interference-based DFOS from an intensity-based or a mixed interference-intensity based DFOS.

© 2006 Institute of Electronics, Information and Communication Engineers