Abstract

With a P-OTDR, we have tested many fibers of a cable and found that the high-PMD contributors were localized within a given region, showing that a partial replacement of the cable is possible.

© 2004 Optical Society of America

PDF Article
More Like This
PMD Distribution Measurement with Polarimetric OTDR assuming Non-Spherical Rayleigh Backscattering

T. Ozeki, K. Nakayama, K. Shinozuka, and K. Iwasaki
FI7 Optical Fiber Communication Conference (OFC) 2004

Measuring the Link Distribution of PMD: Field Trial Using an RS-POTDR

D. Fritzsche, M. Paul, L. Schuerer, A. Ehrhardt, D. Breuer, W. Weiershausen, N. Cyr, H. Chen, and G.W. Schinn
NThE2 National Fiber Optic Engineers Conference (NFOEC) 2008

Fibers and Cables for Ultralow PMD

K. Walker
WJ4 Optical Fiber Communication Conference (OFC) 2003

References

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription