Abstract

We confirmed fiber fuse termination using a fiber fuse terminator consisting of a 1.4 mm-long HAF at a 22 W input. We observed a break in fiber fuse suppression when the HAF was 0.4 mm long.

© 2013 IEICE

PDF Article
More Like This
New propagation mode of fiber fuse with a long-period damage track in hole-assisted fiber (HAF)

Nobutomo Hanzawa, Kenji Kurokawa, Kyozo Tsujikawa, Katsuhiro Takenaga, Shoji Tanigawa, Shoichiro Matsuo, and Shigeru Tomita
OMO5 Optical Fiber Communication Conference (OFC) 2010

Techniques to detect and stop fiber fuses

Kenji Kurokawa
M3J.2 Optical Fiber Communication Conference (OFC) 2014

Detection and Termination System for Optical Fiber Fuse

Takahiro Kinoshita, Norihiko Sato, and Makoto Yamada
WS4_6 OptoElectronics and Communications Conference and Photonics in Switching (OECC_PS) 2013

References

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription