Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Optical Coherence Tomography and Coherence Techniques VI
  • SPIE Proceedings (Optica Publishing Group, 2013),
  • paper 88020F

Four-dimensional optical coherence tomography imaging of total liquid ventilated rats

Not Accessible

Your library or personal account may give you access

Abstract

Optical coherence tomography (OCT) can be utilized for the spatially and temporally resolved visualization of alveolar tissue and its dynamics in rodent models, which allows the investigation of lung dynamics on the microscopic scale of single alveoli. The findings could provide experimental input data for numerical simulations of lung tissue mechanics and could support the development of protective ventilation strategies. Real four-dimensional OCT imaging permits the acquisition of several OCT stacks within one single ventilation cycle. Thus, the entire four-dimensional information is directly obtained. Compared to conventional virtual four-dimensional OCT imaging, where the image acquisition is extended over many ventilation cycles and is triggered on pressure levels, real four-dimensional OCT is less vulnerable against motion artifacts and non-reproducible movement of the lung tissue over subsequent ventilation cycles, which widely reduces image artifacts. However, OCT imaging of alveolar tissue is affected by refraction and total internal reflection at air-tissue interfaces. Thus, only the first alveolar layer beneath the pleura is visible. To circumvent this effect, total liquid ventilation can be carried out to match the refractive indices of lung tissue and the breathing medium, which improves the visibility of the alveolar structure, the image quality and the penetration depth and provides the real structure of the alveolar tissue. In this study, a combination of four-dimensional OCT imaging with total liquid ventilation allowed the visualization of the alveolar structure in rat lung tissue benefiting from the improved depth range beneath the pleura and from the high spatial and temporal resolution.

© 2013 SPIE

PDF Article
More Like This
Improved OCT imaging of lung tissue using a prototype for total liquid ventilation

Christian Schnabel, Sven Meissner, and Edmund Koch
809116 European Conference on Biomedical Optics (ECBO) 2011

4D in vivo imaging of subpleural lung parenchyma by Swept Source Optical Coherence Tomography

S. Meissner, A. Tabuchi, M. Mertens, H. Homann, J. Walther, W. M. Kuebler, and E. Koch
7372_0K European Conference on Biomedical Optics (ECBO) 2009

3D Fourier Domain Optical Coherence Tomography of post perfusion fixated ethanol-filled isolated rabbit lungs

Sven Meissner, Lilla Knels, and Edmund Koch
7372_17 European Conference on Biomedical Optics (ECBO) 2009

Select as filters