Automated volumetric stent analysis of in-vivo intracoronary Optical Coherence Tomography three-dimensional datasets

Not Accessible

Your library or personal account may give you access

Abstract

Intra-vascular Optical Coherence Tomography (IV-OCT) is an appropriate imaging modality for the evaluation of stent struts apposition and coverage in the coronary arteries. Most often, image analysis is performed by a time-consuming manual contour tracing process. Recently, we proposed an algorithm for fully automated lumen morphology and individual stent struts apposition/coverage quantification. In this manuscript further developments allowing for automatic segmentation of the stent contour are presented. As such, quantification of in-stent area, malapposition cross-sectional area (i.e. the area representing the space from the stent surface to the vessel wall) and coverage cross-sectional area (i.e. the area of the tissue covering the stent surface) are automatically obtained. Volumetric measurements of malapposition and coverage are then achieved through the analysis of equally-spaced consecutive IV-OCT cross-sectional images. In addition, uncovered and malapposed struts are automatically clustered through consecutive slices according to their three-dimensional spatial position. Finally, properties of each cluster (e.g. malapposition/coverage volumes and struts spatial location and distribution) are quantified allowing for a volumetric analysis of the implanted device.

Validation of the algorithm was obtained taking as a reference manual measurements performed by an expert cardiologist. 102 in-vivo images, taken at random from 8 different patients, were both automatically and manually analyzed quantifying lumen and stent area. High Pearson’s correlation coefficients (Rarea = 0.99) and Bland-Altman statistics, showing no significant bias and good limits of agreement, proved that the presented algorithm provides a robust and fast tool to automatically estimate apposition and coverage of stent through an entire in-vivo IV-OCT pullback. Such a tool will be important for the integration of this technology in clinical routine and large clinical trials.

© 2011 OSA/SPIE

PDF Article
More Like This
Monitoring coronary artery stent deployment in living human patients with optical coherence tomography

B. E. Bouma, M. Shishkov, K. H. Schlendorf, S. L. Houser, I. K. Jang, and G. J. Tearney
CTuY3 Conference on Lasers and Electro-Optics (CLEO:S&I) 2001

Single-shot Stent Segmentation in Intravascular OCT Pullbacks

Zhao Wang, Michael W. Jenkins, Hiram G. Bezerra, Marco A. Costa, David L. Wilson, and Andrew M. Rollins
BTu4B.5 Biomedical Optics (BIOMED) 2012

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.