Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Time Resolved Detection of Tissue Denaturation during Retinal Photocoagulation

Not Accessible

Your library or personal account may give you access

Abstract

The retinal photocoagulation is an established treatment method for different retinal diseases. The extent of the thermal coagulations depends strongly on the generated temperature increase. Until now the dosage is based on a pool of experience of the treating physicians as well as the appearance of the whitish lesions on the retina. The temperature course during photocoagulation can be measured in real-time by optoacoustics. A frequency-doubled Q-switched Nd:YLF laser (523nm, 75 ns) is used for optoacoustic excitation and a continuous-wave Nd:YAG laser (532nm) with adjustable irradiation time and power for heating of the fundus tissue. The onset of coagulation is determined by a photodiode that is placed directly behind enucleated porcine eyes, which served as a model. The onset of coagulation is observed clearly when scattering sets in. The required power for coagulation increases exponentially with decreasing irradiation time. The first results on rabbit eyes in vivo indicate that the onset of coagulation defined by just barely visibile lesions at a slit lamp sets in at an ED50 threshold temperature of 63°C for an irradiation time of 400 ms. In conclusion, optoacoustics can be used to determine temperatures during retinal laser treatments in real-time. This allows evaluating the time-temperature-dependence of retinal coagulation in vivo.

© 2009 OSA/SPIE

PDF Article
More Like This
Optoacoustic Online Temperature Determination during Retinal Laser Photocoagulation

Kerstin Schlott, Jens Stalljohann, Benjamin Weber, Jochen Kandulla, Katharina Herrmann, Reginald Bimgruber, and Ralf Brinkmann
6632_67 European Conference on Biomedical Optics (ECBO) 2007

Dependence of Optoacoustic Transients on Exciting Laser Parameters for Real-time Monitoring of Retinal Photocoagulation

J. Langejürgen, K. Schlott, M. Bever, K. Hausmann, S. Koinzer, L. Ptaszynski, J. Roider, R. Birngruber, and R. Brinkmann
7373_0K European Conference on Biomedical Optics (ECBO) 2009

Accuracy of real-time optoacoustic temperature determination during retinal photocoagulation

A. Baade, K. Schlott, S. Luft, L. Ptaszynski, M. Bever, R. Birngruber, and R. Brinkmann
80921B European Conference on Biomedical Optics (ECBO) 2011

Select as filters