Estimation of point spread function for scattering effect on cortical tissue image

Not Accessible

Your library or personal account may give you access

Abstract

Optical imaging of an exposed cortex for brain function measurement is an attractive method for both clinical and physiological investigations. Multi-spectral imaging of the exposed cortical tissue enables measuring the activity-dependent changes in oxy- and deoxy haemoglobin independently. Because light propagation in the cortical tissue strongly depends upon wavelength, the blurring by a scattering effect on multi-spectral images depends upon wavelength as well. It is important for more accurate measurement to correct this wavelength-dependent blurring in the multi-spectral images of the exposed cortex. In this study, the relative point spread functions which represent the difference in blurring by wavelength were predicted from the multi-spectral images of a blood vessel in the cortical tissue. The multi-spectral images of the cortical model are calculated by Monte Carlo simulation and wavelength-dependent point spread functions are estimated from the cross section of the blood vessel in the images. The tendency of the wavelength-dependence of relative point spread functions is almost the same as that of the point spread functions predicted from the light propagation in the cortical model. The relative point spread functions estimated from wide blood vessels are broader than those estimated from a narrow blood vessel.

© 2003 SPIE

PDF Article
More Like This
Estimation of the optical path length factor for functional imaging of an exposed cortex by principal component analysis

Kentaro Yokoyama, Motoshi Watanabe, and Eiji Okada
5138_168 European Conference on Biomedical Optics (ECBO) 2003

Estimation of path length factor for measurement of haemoglobin concentration in the exposed cortical tissue

K. Sakaguchi, T. Tachibana, K. Yokoyama, S. Furukawa, E. Okada, T. Katsura, A. Maki, and H. Kawaguchi
WH4 European Conference on Biomedical Optics (ECBO) 2005

Path length correction for haemoglobin concentration measurement in exposed cortex by multi-spectral imaging

K. Sakaguchi, S. Furukawa, E. Okada, T. Katsura, A. Maki, and H. Kawaguchi
TuI12 Biomedical Topical Meeting (BIOMED) 2006

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.