Abstract
Functionalized silicon nitride waveguides are used to detect Raman scattering from trace concentrations of vapor phase chemicals. Parts-per-billion detection limits are measured using single-mode rib and nanoslot waveguides pumped at 785 nm.
© 2017 Optical Society of America
PDF ArticleMore Like This
T. H. Stievater, S. A. Holmstrom, D. A. Kozak, R. A. McGill, M. W. Pruessner, N. Tyndall, W. S. Rabinovich, and J. B. Khurgin
SF2H.2 CLEO: Science and Innovations (CLEO:S&I) 2016
T. H. Stievater, M. W. Pruessner, D. Park, S. A. Holmstrom, R. A. McGill, and W. S. Rabinovich
JW2A.109 CLEO: Applications and Technology (CLEO:A&T) 2012
T. H. Stievater, M. W. Pruessner, D. Park, W. S. Rabinovich, R. A. McGill, S. A. Holmstrom, and J. B. Khurgin
CM4O.4 CLEO: Science and Innovations (CLEO:S&I) 2013