Abstract

An ultra-high sensitive C2H2-QEPAS sensor using an EDFA amplified diode laser was demonstrated. The 33.2 ppb detection sensitivity verified that the design of the reported QEPAS method demonstrated significantly enhanced sensor performance.

© 2018 The Author(s)

PDF Article
More Like This
An Experimental and Theoretical Investigation of CO-QEPAS Sensor Based on a High Power DFB Diode Laser

Yao Tong, Yufei Ma, Ying He, and Xin Yu
JM4A.17 3D Image Acquisition and Display: Technology, Perception and Applications (3D) 2018

Hydrogen Chloride Ultra-high Sensitive Detection based on Quartz-enhanced Photoacoustic Spectroscopy

Yufei Ma, Ying He, Yao Tong, Xin Yu, and Jingbo Zhang
ASu4A.4 Advanced Spectroscopy and Applications (ASA) 2017

Remote, distributed gas sensor based on FEW-QEPAS

Ying He, Yufei Ma, Yao Tong, Xin Yu, and Frank K. Tittel
JW2A.178 CLEO: Applications and Technology (CLEO_AT) 2018

References

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription