Abstract
Ultraviolet light was induced into the FBG hydrogen sensing system to improve the repeatability of the sensor, experiment results show that the relative error in 40 tests under UV- irradiation has been reduced by 54.2%.
© 2018 The Author(s)
PDF ArticleMore Like This
Li Zhu, Jixiang Dai, Yaobin Qi, Gaopeng Wang, Feng Xiang, Yuhuan Qin, and Minghong Yang
s1702 Conference on Lasers and Electro-Optics/Pacific Rim (CLEO/PR) 2017
Chaoqin Wang, Zewen Han, Chenxiang Wang, Yun-Jiang Rao, and Yuan Gong
Th3.4 Optical Fiber Sensors (OFS) 2023
Sergey L. Semjonov, Andrey A. Rybaltovsky, Yuri V. Larionov, Mikhail M. Bubnov, and Evgeny M. Dianov
CA6 Bragg Gratings, Photosensitivity, and Poling in Glass Waveguides (BGPP) 1999