Abstract

We design and fabricate a self-luminescent horizontal slot microdisk resonator using visible light emission of Si-ncs for biosensing. The surface sensitivity of the sensor is calculated as 2.46 nm/(nm*RIU) using FDTD method.

© 2011 OSA