Abstract

We report on an idler octave-spanning (1.6 - 3.5µm) cw titanium-sapphire pump-resonant signal-resonant optical parametric oscillator delivering 10 to 50 mW, for multi-species trace gas sensing based on cavity ring down spectroscopy.

© 2010 The Optical Society