We demonstrated a method of characterizing temperature sensitivity of ytterbium-doped fiber amplifiers based on deriving Stark parameters from measured emission and absorption spectra. Temperature sensitivity is found to be mainly determined by Pout/Ppump, when Pout/Ppump>0.4.