Abstract

We report the first practical in vivo two-photon pO<sup>2</sup>measurements in cortical microvasculature, made possible by using a two-photon-enhanced phosphorescent nanoprobe. New method features ~250-?m measurement depth, sub-second temporal resolution and requires low probe concentration.

© 2010 OSA