Abstract
The index of refraction of fused quartz glass was determined for 24 wavelengths from 0.34669 to 3.5078 microns, using the minimum deviation method. The whole range is covered with a single instrument. The variation in index between samples was determined and no definite variations in dispersion were observed. Possible relations between purity and index are discussed.
© 1954 Optical Society of America
Full Article | PDF ArticleCorrections
W. S. Rodney and R. J. Spindler, "Errata," J. Opt. Soc. Am. 44, 889_3-889 (1954)https://opg.optica.org/josa/abstract.cfm?uri=josa-44-11-889_3
More Like This
I. H. Malitson
J. Opt. Soc. Am. 55(10) 1205-1209 (1965)
D. H. Rank, H. E. Bennett, and D. C. Cronemeyer
J. Opt. Soc. Am. 44(1) 13-16 (1954)
Georg Hass and Calvin D. Salzberg
J. Opt. Soc. Am. 44(3) 181-187 (1954)