Quantifying changes in oxygen saturation of the internal jugular vein in vivo using deep neural networks and subject-specific three-dimensional Monte Carlo models

Not Accessible

Your library or personal account may give you access

Abstract

Central venous oxygen saturation (ScvO2) is an important parameter for assessing global oxygen usage and guiding clinical interventions. However, measuring ScvO2 requires invasive catheterization. As an alternative, we aim to noninvasively and continuously measure changes in oxygen saturation of the internal jugular vein (SijvO2) by a multi-channel near-infrared spectroscopy system. The relation between the measured reflectance and changes in SijvO2 is modeled by Monte Carlo simulations and used to build a prediction model using deep neural networks (DNNs). The prediction model is tested with simulated data to show robustness to individual variations in tissue optical properties. The proposed technique is promising to provide a noninvasive tool for monitoring the stability of brain oxygenation in broad patient populations.

© 2024 Optica Publishing Group

Full Article  |  PDF Article
More Like This
Multiwavelength optoacoustic system for noninvasive monitoring of cerebral venous oxygenation: a pilot clinical test in the internal jugular vein

Yuriy Y. Petrov, Irina Y. Petrova, Igor A. Patrikeev, Rinat O. Esenaliev, and Donald S. Prough
Opt. Lett. 31(12) 1827-1829 (2006)

Monte Carlo modeling of optoacoustic signals from human internal jugular veins

Igor Patrikeev, Yuriy Y. Petrov, Irina Y. Petrova, Donald S. Prough, and Rinat O. Esenaliev
Appl. Opt. 46(21) 4820-4827 (2007)

Observation of blood motion in the internal jugular vein by contact and contactless photoplethysmography during physiological testing: case studies

Gennadi Saiko, Timothy Burton, Yasuyuki Kakihana, Kosaku Hatanaka, Ohtonari Takahito, and Alexandre Douplik
Biomed. Opt. Express 15(4) 2578-2589 (2024)

Supplementary Material (1)

NameDescription
Supplement 1       Detailed methods and results.

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (5)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (2)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.