Abstract
In this Letter, a new method is proposed to further improve the detection sensitivity of the gas sensor based on off-axis integrated cavity spectroscopy (OA-ICOS) using a distributed feedback laser operating in the near-infrared at 1653 nm that relies on implementation of wavelength modulation and radio frequency (RF) white noise perturbation to diode laser current. More than sixfold improvement in detection limit is achieved for an RF noised wavelength-modulated OA-ICOS compared to the unperturbed conventional OA-ICOS approach.
© 2019 Optical Society of America
Full Article | PDF ArticleMore Like This
Jingjing Wang, Xing Tian, Yang Dong, Gongdong Zhu, Jiajin Chen, Tu Tan, Kun Liu, Weidong Chen, and Xiaoming Gao
Opt. Express 27(21) 30517-30529 (2019)
Faisal Nadeem, Julien Mandon, Simona M. Cristescu, Amir Khodabakhsh, and Frans J. M. Harren
OSA Continuum 2(9) 2667-2682 (2019)
Kaiyuan Zheng, Chuantao Zheng, Qixin He, Dan Yao, Lien Hu, Yu Zhang, Yiding Wang, and Frank K. Tittel
Opt. Express 26(20) 26205-26216 (2018)