Evaluation of Multivariate Calibration Models Transferred between Spectroscopic Instruments: Applied to near Infrared Measurements of Flour Samples

Not Accessible

Your library or personal account may give you access

Abstract

In a setting where multiple spectroscopic instruments are used for the same measurements it may be convenient to develop the calibration model on a single instrument and then transfer this model to the other instruments. In the ideal scenario, all instruments provide the same predictions for the same samples using the transferred model. However, sometimes the success of a model transfer is evaluated by comparing the transferred model predictions with the reference values. This is not optimal, as uncertainties in the reference method will impact the evaluation. This paper proposes a new method for calibration model transfer evaluation. The new method is based on comparing predictions from different instruments, rather than comparing predictions and reference values. A total of 75 flour samples were available for the study. All samples were measured on ten near infrared (NIR) instruments from two instrumental platforms, five NIR instruments from each platform. Protein content was quantified for all 75 samples and used as the reference variable during modelling by partial least squares regression. By adding artificial noise to first the spectroscopic measurements and then the reference values, this paper highlights the problems of including reference values in the evaluation of a model transfer, as uncertainties in the reference method impact the evaluation. At the same time, this paper highlights the power of the proposed model transfer evaluation, which is based on comparing predictions obtained from the different instruments. In this way, the impact of uncertainties originating from the reference method is minimised.

© 2016 The Author(s)

PDF Article
More Like This
Rapid detection of talc content in flour based on near-infrared spectroscopy combined with feature wavelength selection

Changhao Bao, Changhao Zeng, Jinming Liu, and Dongjie Zhang
Appl. Opt. 61(19) 5790-5798 (2022)

Evaluation of univariate and multivariate calibration strategies for the direct determination of total carbon in soils by laser-induced breakdown spectroscopy: tutorial

Wesley Nascimento Guedes, Diego Victor Babos, Vinícius Câmara Costa, Carla Pereira De Morais, Vitor da Silveira Freitas, Kleydson Stenio, Alfredo Augusto Pereira Xavier, Luís Carlos Leva Borduchi, Paulino Ribeiro Villas-Boas, and Débora Marcondes Bastos Pereira Milori
J. Opt. Soc. Am. B 40(5) 1319-1330 (2023)

Model transfer method based on piecewise direct standardization in laser-induced-breakdown spectroscopy

Ge Xie, Lanxiang Sun, Dong Shang, Yuan Gao, Xin Ling, and Xiuye Liu
Appl. Opt. 61(30) 9069-9077 (2022)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.