Extended photoacoustic transport model for characterization of red blood cell morphology in microchannel flow

Open Access Open Access

Abstract

The dynamic response behavior of red blood cells holds the key to understanding red blood cell related diseases. In this regard, an understanding of the physiological functions of erythrocytes is significant before focusing on red blood cell aggregation in the microcirculatory system. In this work, we present a theoretical model for a photoacoustic signal that results when deformed red blood cells pass through a microfluidic channel. Using a Green’s function approach, the photoacoustic pressure wave is obtained analytically by solving a combined Navier-Stokes and photoacoustic equation system. The photoacoustic wave expression includes determinant parameters for the cell deformability such as plasma viscosity, density, and red blood cell aggregation, as well as involving laser parameters such as beamwidth, pulse duration, and repetition rate. The effects of aggregation on blood rheology are also investigated. The results presented by this study show good agreements with the experimental ones in the literature. The comprehensive analytical solution of the extended photoacoustic transport model including a modified Morse type potential function sheds light on the dynamics of aggregate formation and demonstrates that the profile of a photoacoustic pressure wave has the potential for detecting and characterizing red blood cell aggregation.

© 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

1. Introduction

Red blood cells (RBCs) have the deformation capability in microcapillaries. RBC membrane allows cells to squeeze, deform, and reform through capillaries. The geometric shape of RBC provides an efficient transport through narrow capillaries and increases the surface area in order to maximize oxygen transport. The alternation of the cell membrane deformability under some disease conditions is significantly different than healthy ones [1,2]. To illustrate, the RBCs of sickle cell disease have the most significant loss of deformability because of having different morphologies depending on its density [3–6]. The small changes in the morphology of RBCs are characterized by the absorption-based contrast of photoacoustic (PA) imaging which is complementary to other imaging modalities in terms of contrast mechanism, penetration, spatial resolution, and temporal resolution [7–18].

Recent studies seek to provide insights to measure RBC deformability via experimental techniques such as atomic force microscopy (AFM) [19–22], micropipette aspiration technique [23–26], optical and magnetic tweezers [27–32], microfluidic device techniques [2, 33–35]. Moreover, mathematical (analytical and numerical) models have been also presented in order to distinguish cell types and identify several diseases [28,32,36–38]. Using these experimental techniques and mathematical methods, intrinsic mechanical properties of RBCs (geometry and cytoplasmic viscosity), and viscoelastic properties of their membrane cortex structure are assessed. The shear modulus of RBC is inferred using optical tweezers while two microspheres attached to the opposite sides of RBC are trapped. Unless the laser beam is tightly focused on microbeads attached to the cells, the cell damages occur because of temperature rise [39]. The stiffness of cells is measured via AFM by isolating the AFM system from surrounding vibrations [40]. Micropipette aspiration is another technique for investigating cellular mechanical properties via aspirating pressure. Although this technique provides a broad range of applications, the unstable base pressure coming from vapor evaporation in the aspiration chamber may occur owing to the dependence of operator’s skills [26]. Furthermore, magnetic tweezer has been applied to monitor mechanical properties of single molecules, intermolecular bonds, and whole cells. It gives information about complex modulus of elasticity and the local viscoelasticity of the cells. However, it is required to ensure highly localized magnetic fields, field gradients, and spherical magnetic beads with various sizes to obtain more accurate viscoelastic properties of the cells [41].

The hemoglobin within RBCs as an endogenous contrast agent absorbs visible and near-infrared light, which enables to image RBCs without staining via PA microscopy [7,9,42,43]. Even though the image does not give information about their shapes and structures, PA signal with amplitude, width, rise, and relaxation time enables to observe morphological changes in RBCs. The changes in the PA response depending on the cell elastic properties differentiate between healthy RBCs and diseased or damaged RBCs [15,44,45]. In the context of the detection of individual RBCs, there are several recent PA studies utilizing theoretical, experimental, and computational methods [46]. Saha et al. firstly described the PA pressure field generated by a collection of erythrocytes with the help of a theoretical model developed by Diebold et al. [46–49]. In vivo RBC age or surface charge density was presented using a two dimensional simulation study based on the PA signal properties of erythrocyte aggregation level which is related to the suspending medium [47,49]. In another work, Saha and Kolios not only presented experimental results but also showed that the theoretical simulation study assessing PA signals could be followed to determine the degree of aggregation [50]. This frequency domain theoretical model was also used for a computer simulation study in order to differentiate intraerythrocytic stages of malarial parasite such as normal, ring, trophozoite, and schizont stages [46].

Mathematical models to calculate PA signal produced from one or more cells have been reported in a limited number of studies [48, 50–52]. Generally, cells were approximated as fluid spheres. The PA pressure wave produced by a collection of absorbing spheres was usually considered as a linear superposition of spherical waves emitted by individual sources [50]. It was assumed that acoustic waves coming from an absorbing sphere were not influenced by other particles in the medium, and all double and multiple scatterings of light beam were also ignored. The other study utilizing mathematical models was the description of PA signal in the time domain produced from one or more cells using an absorption model. The results of this study demonstrated that PA amplitude does not depend on the position of the cells in the stimulation field. In addition, the validity of the model was confirmed with experiments and simulations prior to experiments were carried out for the elimination of blind estimation [51]. Li et al. solved the PA Helmholtz equation by using the separation of variables method in spheroidal coordinates for a spheroidal droplet which is a more realistic geometric shape than a sphere [52]. When the PA detection of RBCs and their nuclei are considered, this derivation provides an opportunity to obtain a numerical simulation for practical uses of analyzing experimental data.

In this paper, we establish a PA wave expression for RBCs by using an extended Navier-Stokes equation when they travel into a microvessel. Our approach takes into consideration the interaction of cells to investigate RBC aggregation and its effect on blood rheology. We model the cells as spheres and the interaction forces between two cells cause the formation of aggregate clusters. We also analyze PA signal characteristics in the dynamic modes by means of RBC aggregation associated with complex hemorheological changes as well as viscosity. The motion of deformable cells can be described by the immersed boundary method based on Navier-Stokes equation. In order to evaluate the degree of aggregation which is related to their surface structure and their shape, the intercellular interaction is represented by the Morse type potential function [53]. Using a Green’s function approach, an extended PA wave equation including a modified Morse type potential is solved analytically in detail. We obtain the PA pressure wave generated by normal and pathological RBCs associated with distinctive parameters such as a coefficient of surface energy and a scaling factor controlling the interaction decay behavior. The PA signal not only includes determinant parameters for the deformability of the cell such as plasma viscosity, density, and RBC aggregation but also contains laser parameters such as beamwidth, pulse duration, and repetition rate since the temporal profile is considered Gaussian rather than the Dirac delta function. Therefore, the approach given in this work can be useful to analyze the deformability of RBCs by taking advantage of the PA phenomena. The study of the mathematical modeling and the experimental design and detection of PA waves in micro-channels can be helpful for an appropriate choice of therapy.

2. Method

2.1. Combined Navier-Stokes and heat transfer equations for a compressible flow

In this section, we present an expression for PA waves resulted from RBCs which travel into microvessels by solving the extended Navier-Stokes equation including RBC aggregation kinetics. The schematic of our model is shown in Fig. 1. The red blood cell is radiated with a pulsed laser. The PA waves resulted from the red blood cell are received by the detector. The interaction between the red blood cells is depicted by the arrows.

 figure: Fig. 1

Fig. 1 The schematic of the model.

Download Full Size | PDF

Absorption of light leads to a thermal expansion

ρ0cpT(r,t)tκ2T(r,t)=H(r,t)
where ρ0 is the mass density, cp is the constant-pressure heat capacity per unit mass, κ is the thermal conductivity, T(r, t) is the temperature rise at position r and time t, and H(r, t) is the heating function defined as the optical energy deposited per unit time and per unit volume [54,55].

As a result of the thermal expansion, acoustic waves are generated. In this process, the mass density obeys the continuity equation

ρt+(ρv)=ρβT(r,t)t
where ρ, v, and β are the mass density, the velocity field, and the coefficient of the volume thermal expansion, respectively [55,56]. The velocity field v holds for the Navier-Stokes equation
ρ[vt+v(v)]=p+η2v+(ζ+1/3η)(v)
where p is the pressure, η is the shear viscosity, and ζ is the bulk viscosity [57]. The thermal diffusion can be neglected since the pulse duration is very short so that the combination of Eq. (1) with Eq. (2) gives
ρt+ρv=βH(r,t)cp.
Under the assumptions of small amplitude photoacoustic wave and sufficiently small source power, the pressure and density can be written as p = p0 + δp and ρ = ρ0 + δρ where p0 and ρ0 are the equilibrium pressure and density with δpp0 and δρρ0, respectively [57]. After the linearizations of the Eqs. (3) and (4) under the assumption of small amplitude photoacoustic wave with constant p0 and ρ0, we obtain
δρt+ρ0v=βH(r,t)cp
and
ρ0vt=δp+η2v+(ζ+13η)(v).
In order to simulate the blood flow in a microfluidic device for the deformation of a single red blood cell in a microvessel, the relationship between the mass density and the velocity field in the fluid can be obtained by solving the extended Navier-Stokes equation with a body force denoted by f(r, t)
ρ0vt=δp+η2v+ν(v)+f(r,t),
and
f(r,t)=n=1N[FnΔ(rYn(t))]
where ν=(ζ+13η) is the blood viscosity. Here, Fn is the aggregation force between two cells, n is the index of RBCs and N is the total number of interacting RBCs. The interaction force between RBCs, Fn is modeled by the Morse potential, and Δ is an interpolation function (interpolation kernel) which enables to model the interaction between the immersed structure and the fluid. Here, Yn is the position of the center of the red blood cell and r is the flow position. The cells aggregate slowly and an equilibrium configuration occurs when the intercellular interaction is balanced via the membrane forces after the deformation of the RBC membrane in microfluidic devices [58,59].

Combining Eqs. (5) and (7), the PA wave resulted from a collection of erythrocytes (which is considered as an optical absorber) can be obtained by solving the following equation

1cs22p(r,t)t2=2p(r,t)+ηρ0cs2[2p(r,t)tΓ2H(r,t)]f(r,t)+βcpH(r,t)t
where cs is the speed of sound, Γ=βcs2cp, δp=cs2δρ, and η=(ζ+43η). Thus, Eq. (9) can be written in the following form
2p(r,t)+ηρ0cs22p(r,t)t1cs22p(r,t)t2=S(r,t)
where S(r, t) is the source term which can be described by
S(r,t)=βcpH(r,t)t+Γηρcs22H(r,t)+f(r,t).
The first and second source terms on the right-hand side of Eq. (11) are due to the heat-producing, optical absorption within the two-phase sphere composed of one absorber (red blood cell) and fluid (blood plasma). Here, the fluid and the solid occupy a domain, but they do not intersect; thus, we model the fluid-structure interaction with the immersed boundary method and the boundary integral method. Moreover, the basic behaviour of the interaction forces between two RBCs is illustrated in Fig. 2. The third source term on the right-hand side of Eq. (11) is due to the interaction force between the two RBCs. Therefore, we can write the source term as S(r, t) = S1(r, t) + S2(r, t) + S3(r, t).

 figure: Fig. 2

Fig. 2 Aggregation force (F) corresponding to the various aggregation rates vs function of separation between cell surfaces (β(d−r0)) for (a) case 1 [65, 72]: D = 3 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 3 μm; case 2 [65, 72]: D = 2.1 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 2.5 μm; case 3 [65, 72]: D = 2.1 × 10−17 J/m2, β = 6 × 105 m−1, r0 = 2 μm, (b) Dextran 70 [74]: D = 5.75 × 10−17 J/m2, β = 6 × 105 m−1, r0 = 2 μm; Dextran 150 [74]: D = 56.4 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 3 μm.

Download Full Size | PDF

Using the Fourier convention, {p(r,t),S(r,t)}=12π{p˜(r,ω),S˜(r,ω)}exp(iωt)dω, the wave equation can be expressed in the frequency domain

2p˜(r,ω)+ω2p˜(r,ω)cs2(1iωB)=S˜(r,ω).
where B=ηρ0cs2. The solution of Eq. (9) can be found by utilizing the Green’s function approach [60]. The Green’s function for Eq. (12) is given by
G˜(r,r;ω)=14π|rr|exp(ik1|rr|)
where k12=ω2cs2(1iω) [60]. The heating function can be decomposed into the spatial and temporal parts as follows
H(r,t)=A(r)I(t).
The heating due to the pulsed laser beam is very localized in both time and space so that the temporal and spatial parts of the heating function can be expressed by Gaussian functions. The radial part of the heating function can be written as
A(r)=p0(r)cpcs2β.
Here, p0(r) is the initial pressure rise just after the laser pulse and it is defined by
p0(r)=βT(r)cκ
where cκ is the isothermal compressibility [61,62]. This initial pressure rise can be decsribed by a Gaussian function as can be seen in the following section [62]. The temporal profile can be described by
I(t)=exp(t2/2τ2)2πτ2
where τ is the pulse duration of the laser.

Substituting Eqs. (15) and (17) into Eq. (14) leads to

S1(r,t)=p0(r)cs2t[exp(t2/2τ2)2πτ2]=12πτ3p0(r)cs2texp(t2/2τ2).

After applying the Fourier transform to S1 yields

S˜1(r,ω)=12πτ3p0(r)cs2+texp(t2/2τ2)exp(iωt)dt=p0(r)iωcs2exp(τ2ω2/2).
Moreover, the second source term in Eq. (11) can be written as follows
S2(r,t)=ηTρ0cs2[exp(t2/2τ2)2πτ2]2p0(r).

The Fourier transform of S2(r, t) is

S˜2(r,ω)=ηΓρcs22p0˜(r)+exp(t2/2τ2)2πτ2exp(iωt)dt=ηΓρcs22p0˜(r)exp(τ2ω2/2).

The function f(r, t) in Eq. (9) can be expressed by

f(r,t)=n=1N[FnΔ(rYn(t))]
where n is the index of the particle and N is the number of absorbing particles (RBCs) referring to the radius of clusters of RBC aggregates.

According to the immersed boundary method, we consider an compressible three-dimensional deformable structure in a RBC membrane immersed in an compressible fluid domain. In this regard, the combination of the fluid and structure is possible, provided that they do not intersect [59,63–65]. Based on this method, the contribution of each RBCs whose center of mass is located at Yn to the flow at position r (which is considered as a distance between the source and the detector) is smoothed by a Gaussian distribution kernel. The choice of Gaussian kernel is a good assumption to study problems involving fluid-structure interactions in which an elastic structure is immersed in a viscous fluid. This method describes the fluid-membrane interaction between the flow field and deformable cells

Δ(X)=(2πh2)3/2exp[(rr)22h2]exp(t2/2τ2)2π
where X = (rYn(t)), and h is the standard deviation of the kernel, h=Rπ. Here, r′ varies between 0 and R and chosen as Yn.

The aggregating force between two cells represented by Fn in Eq. (22) is modeled by a Morse type potential function. The Morse type potential function was also employed to describe the interactions of RBCs [53,66]. The parameters of the Morse potential function for intercellular interaction are summarized in Table 1 [67–71] and Table 2 [65, 72] (In Table 1, the physical properties are mapped onto the dimensionless properties for the consistency of the simulation with the experiment. The scaling procedure relates the model’s non-dimensional units to the physical units [70].). Figure 2 shows the aggregation forces corresponding to the various aggregation strengths which are summarized in Tables 3 and 4. These red blood cell aggregation forces calculated from selected parameters show a good agreement with the experimental ones (Fig. 2) [73–75]. These experimental forces are in the range of 2–12 pN [73], 14–23 pN, and 43–169 pN [74,75]. The measurements of interaction forces between red blood cells in aggregates and the measurements on dextran-induced aggregation of red blood cells were obtained by optical tweezers and atomic force microscopy-based single cell force spectroscopy, respectively.

We use the following Morse function

f(r,t)=2βD(e2β(r0d)eβ(r0d))(2πh2)3/2exp[(rr)22h2]exp(t2/2τ2)2π
to detect the acoustic pressure of non-aggregated and aggregated erythrocytes, where β, D, r0, and d are a scaling factor controlling the decay behavior of interaction of RBC, the coefficient of surface energy, the zero force separation, and the local distance between two surface elements of the cells, respectively. It is important to note that the number of absorbing particles (RBCs) depends on the radius of clusters of RBC aggregates (R). This number is expressed in terms of the radius of the defined region of interest since the amplitude of PA signal depends on radius of the absorber. In our case, N = 1. In our calculations, the interaction distance of the Morse potential regarding the immersed boundary method is calibrated with the distance between the source and detector in the case of the third source since our model couples the Navier-Stokes equation with the cell interaction and the bio-heat transfer equation. To see the contribution coming from the aggregation process on the photoacoustic wave, the interaction distance is the distance between detector and the absorber. For attractive forces, the value of the scaling force is negative when r0 < d. Conversely, if the value of the force is positive when r0 > d, the force is indicated by a repulsive force. The attractive force is crucial to represent an intercellular interaction through the Morse-type potential energy function. Under this intercellular interaction, the aggregation occurs either by increasing D or by decreasing β, which is shown in Figs. 24. Moreover, zero force length may raise the depletion thickness as well as equilibrium distance of the RBCs in aggregates. In Fig. 2, the strongest attractive force among three cases is observed in case 1. In order to examine the modified Morse function, aggregation forces which represent the different RBC aggregation as a function of separation between cell surfaces and the time scale of acoustic wave are illustrated in Figs. 3 and 4, respectively. The normalized amplitudes of modified aggregation forces (Figs. 3 and 4) exhibit a similar behavior, as shown in Fig. 2.

 figure: Fig. 3

Fig. 3 Normalized ∇·F (modified aggregation forces) vs function of separation between cell surfaces (β(d−r0)) for case 1 [65, 72]: D = 3 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 3 μm; case 2 [65,72]: D = 2.1 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 2.5 μm; case 3 [65,72]: D = 2.1 × 10−17 J/m2, β = 6 × 105 m−1, r0 = 2 μm.

Download Full Size | PDF

 figure: Fig. 4

Fig. 4 Normalized ∇·F which represents the different red blood cell aggregation conditions with different intercellular strengths vs time scale of acoustic wave, t(s) for case 1 [65,72]: D = 3 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 3 μm; case 2 [65,72]: D = 2.1 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 2.5 μm; case 3 [65, 72]: D = 2.1 × 10−17 J/m2, β = 6 × 105 m−1, r0 = 2 μm.

Download Full Size | PDF

Tables Icon

Table 1. Model parameters [67,68,70].

Tables Icon

Table 2. Model parameters [65,72].

Tables Icon

Table 3. Constitutive parameters for the three various forces resulting from the RBC aggregation [65,72,73].

Tables Icon

Table 4. The model parameters for the measured dextran-induced aggregation forces of red blood cells [74].

2.2. Solution of the extended photoacoustic wave equation for a Gaussian radial absorption profile

In this section, we describe the radial profile by a Gaussian function with the standard deviation or beamwidth of the laser σ

p0(r)=p0exp(r22σ2)θ(r)θ(r+R)
where θ is the Heaviside step function. Here, the initial pressure p0 is created inside the object so that the initial pressure distribution can be defined as Eq. (25). The following integral can be written as a summation of three terms corresponding to three different sources as follows
p˜(r,ω)=G˜(r,r;ω)S˜(r,ω)d3r
where S=S1+S2+S3. The contribution coming from the first source is
p1˜(r,ω)=ip04πωcs2exp(τ2ω22)02πdϕ0R(r)2dr1+1exp[ik1|rr|]|rr|dμ
where |rr|=r2+r22rrμ, μ′ = cos θ′, and
1+1exp[(ik1)(r2+r22rrμ)](r2+r22rrμ)dμ=1irrk1[exp[ik1(rr)]exp[ik1(r+r)]].
So the solution due to the first source becomes
p1(r,t)=p022πrcs20Rdrrexp(r22σ2)×exp[τ2ω22+ik1(r±r)iωt][cs1iωBω]ωdω,
Using the Taylor-series expansion
1iωB=1iBω2+18(Bω)2+O((Bω)3),
we evaluate the integral in Eq. (28) [60,76]
I=exp[τ2ω22+(iω(r±r)cs1iωB)iωt]dωiB2ωexp[τ2ω22+(iω(r±r)cs1iωB)iωt]dω.

The exponential term can be further expanded [60,76,77]

exp[iω(r±r)cs1iωB]~exp[iω(r±r)cs]Bω[ω(r±r)eiω(r±r)cs]2cs.

Thus, we obtain [76,77]

p1(r,t)=p022π1rcs0Rdrrexp(r22σ2)×{exp[τ2ω22+(iω(r±r)cs)iωt]dωiB2ωexp[τ2ω22+(iω(r±r)cs)iωt]dω}.

Here, it is important to note that after a series of numerical calculation, we see that the contribution coming from the high order terms is negligible. This case can also be analyzed analytically. For large values of ω, the compactly supported function exp(−τ2ω2/2) dominates the higher order terms resulted from the series expansion. On the other hand, the physical parameters pulse duration (τ) and B=η/(ρ0cs2) are also on the orders of 10−9 and 10−12, respectively so that the value of the integral is already very small for small values of ω. Therefore, based on the relatively small values of τ and B and the predominance of exp(−τ2ω2/2) term for large values of ω, the influence of the integral due to the higher order terms is negligible.

So that the p1(r, t) can be simplified as follows

p1(r,t)=[p022π1rcs][J1a+iB2J1b]
where
J1a=0Rdrrexp(r22σ2)[2πexp((cst+rr)22τ2cs2)τ2πexp((cst+rr)22τ2cs2)τ]
and
J1b=0Rdrrexp(r22σ2)[i2π(cst+r+r)exp((cst+r+r)22τ2cs2)τ3cs+i2π(cst+rr)exp((cst+rr)22τ2cs2)τ3cs].

Substituting the results of the integrals J1a and J1b into Eq. (33) enables to find the pressure due to S1(r, t)

J1a=τσ2cs2(σ2+τ2cs2)3/2exp[2R(rcst)+2(rcst)2+R22τ2cs2R22σ2](2πσ(rcst){erf[σ2(r+R+cst)+Rτ2cs22τσcsσ2+τ2cs2]×exp[(r+Rcst)22τ2cs2+σ2(rcst)22τ2cs2(σ2+τ2cs2)+R22σ2]+erf[σ2(r+Rcst)+Rτ2cs22τσcsσ2+τ2cs2]exp[(σ2(r+Rcst)+Rτ2cs2)2σ2(σ2+τ2cs2)+(rcst)22τ2cs2]]2τcsσ2+τ2cs2exp[(rcst)22τ2cs2]exp[2R(rcst)τ2cs2]1})×θ(r|Rcst|)θ(r+R+cst)
where erf(x) is the error function. It is important to note that the value of the integral J1b is sufficiently small compared to the integral J1a.

The solution of the PA equation due to the second source in time domain can be evaluated by using the Taylor series expansion in the following p2(r, t) expression similar to the calculation of p1(r, t)

p2(r,t)=ηTiρcs20Rrdr2p0(r)×exp[τ2ω22+ik1(r±r)iωt][cs1iωBω]dω.
Hence, p2 simplifies to
p2(r,t)=ηΓiρcs0Rrdr2p0(r)×{exp[τ2ω22+iω(r±r)csiωt]ωdωiB2exp[τ2ω22+iω(r±r)csiωt]dω}.
The first integral with respect to ω in Eq. (38) can be calculated by using the residue theorem. Applying the residue theorem at z=0
J=exp[τ2z22+iz(r±R)csizt]zdz,
J={πilimz0zexp[τ2z22+iz((r±R)cst)]zif(r±Rcst)>0πilimz0zexp[τ2z22+iz(r±Rcst)]zif(r±Rcst)<0.

The contribution coming from integral J is zero so that p2(r, t) becomes

p2(r,t)=BηΓp042πρrcs0Rdrr[r2exp(r22σ2)σ4exp(r22σ2)σ2]×[2πexp[(cst+r+r)22τ2cs2]τ2πexp[(cst+rr)22τ2cs2]τ].
We can express p2(r, t) in the following form
p2(r,t)=[BηΓp042πρrcs](J2aJ2b)
where
J2a=0Rdrr[(r)2exp(r22σ2)σ4exp(r22σ2)σ2]×[2πexp[(cst+rr)22τ2cs2]τ]
and
J2b=0Rdrr[(r)2exp(r22σ2)σ4exp(r22σ2)σ2]×[2πexp[(cst+rr)22τ2cs2]τ].
Moreover, the third PA wave, p3(r, t) due to the third source corresponding to aggregation force is
p3(r,t)=csτ4i2πr0Rrdrf(r,ω)×{exp[τ2ω22+iω(r±r)csiωt]ωdωiB2exp[τ2ω22+iω(r±r)csiωt]dω}.
The first integral over ω in Eq. (45) has the same form as shown in Eq. (38), and it can be evaluated by the contour integration method. We can rewrite Eq. (45) in the following form which yields the pressure wave of non-aggregated and aggregated erythrocytes
p3(r,t)=csτB42πr(J3aJ3b)
where
J3a=βD[e2β(r0d)eβ(r0d)]πh50Rdrr(rr)exp[(rr)22h2]×[2πexp[(cst+r+r)22τ2cs2]τ]
J3b=βD[e2β(r0d)eβ(r0d)]πh50Rdrr(rr)exp[(rr)22h2]×[2πexp[(cst+rr)22τ2cs2]τ].

By evaluating the integral in Eq. (47), we obtain

J3a=βD(eβ(r0d)1)πτh5×{τh2cs2(τ2cs2+h2)5/2exp[r(rtcs)τ2cs2+h2r2cs2+t22τ2+β(r0d)r22h2]×[2τh2csτ2cs2+h2(tcs2r)exp[τ2r2cs+h2rtτ4cs3+τ2h2cs]+exp(τ4r2cs4+2τ2h2rtcs3+h4r2+h4t2cs22τ4h2cs4+2τ2h4cs2)2πh×(h2(cs2(τ2+t2)+2r23rtcs)+τ2cs2(τ2cs22r2+rtcs))×erf[τ2rcs2h2(rtcs)2τhcsτ2cs2+h2]]τh2cs2(τ2cs2+h2)5/2exp[r(rtcs)τ2cs2+h2r2+R2+t2cs22b2cs2+β(r0d)r2+R22h2]×(2τcsτ2cs2+h2(τ2Rcs2+h2(2r+R+tcs))×exp(r(rtcs)τ2cs2+h2+tcs(r+R)rRτ2cs2+rRh2)+exp[τ4cs4(r2+R2)+2τ2h2cs2(rtcs+R2)+h4(r2+R2+t2cs2)2τ2h2cs2(τ2cs2+h2)]×2πh(h2(cs2(τ2+t2)+2r23rtcs)+τ2cs2(τ2cs22r2+rtcs))×erf[τ2cs2(rR)h2(r+Rtcs)2τhcsτ2cs2+h2])θ(r|Rcst|)θ(r+R+cst)}.

Here, the Heaviside step function, θ, is introduced to take into consideration the propagation time when observation point is outside the PA absorber [61, 62]. The integrals J3a and J3b contribute significantly to the PA signal. We note that the calculation of the integral J3a is very similar to the one of the integral J3b.

3. Numerical/simulation parameters

The behavior of a normalized PA wave produced by a RBC as a function of normalized time is illustrated in Fig. 5 for two different pulse durations (τ=1 and 5 ns) and beamwidths (σ = 6 and 8 μm). The PA wave stemming from the first source is calculated from Eq. (33). In Fig. 5, the effects of the laser beamwidth and pulse duration on the PA signal are observed. The density, and the speed of sound within the cell, the radius of absorber are taken as ρ = 1000 kg/m3, cs=1520 m/s, R=8 μm [78], respectively. Fig. 6 shows the power spectrum of the PA signal given in Fig. 5. Eventhough the change in the PA amplitude is small in the time domain, it becomes more visible in the frequency domain. Fig. 7 illustrates the effects of the laser beamwidth and pulse duration on the PA signal for the detector position (2 mm away from the center of the absorber [79,80]) regarding the feasibility of experimental realization in the presence of the first source. Fig. 8 and Fig. 9 show the effects of the plasma viscosity on the normalized PA wave, an ultrasonic detector located at r =2R and 500 μm, respectively [79,81]. In Figs. 815, the shear and bulk viscosities are taken as η = 1.2, 1.3 mPa.s, ζ = 4.5, 5, 6, 18.4, and 22.9 mPa.s, respectively [74,82–84] as can be seen in the following section.

 figure: Fig. 5

Fig. 5 Normalized PA wave p(r,t)/p0 generated by first source vs normalized time cst/R, an ultrasonic detector located at position r = 2R for the two different pulse durations (a) τ = 1 and (b) 5 ns with different beamwidths σ = 6 μm (dashed line) and 8 μm (solid line), where R = 8 μm.

Download Full Size | PDF

 figure: Fig. 6

Fig. 6 Normalized power spectral density of the photoacoustic wave in Fig. 5, an ultrasonic detector located at the position r = 2R for the two different pulse durations (a) τ = 1 and (b) 5 ns with the different beamwidths σ = 6 μm (dashed line) and 8 μm (solid line), where R = 8 μm.

Download Full Size | PDF

 figure: Fig. 7

Fig. 7 Normalized PA wave p(r,t)/p0 generated by first source vs time time (μs), an ultrasonic detector located at position r = 2 mm for the two different pulse durations (a) τ = 1 with different beamwidths σ = 8 μm (dashed line) and 6 μm (solid line), where R = 8 μm and (b) 5 ns with different beamwidths σ = 8 μm (dashed line) and 6 μm (solid line), respectively where R = 8 μm.

Download Full Size | PDF

 figure: Fig. 8

Fig. 8 The effects of viscosity on normalized PA wave p(r,t)/p0 vs normalized time cst/R, an ultrasonic detector located at r = 2R for two different pulse durations (a)–(b) τ = 1, (c)–(d) 5 ns with different beamwidths σ = 6 (dashed line) and 8 μm (solid line), where R = 8 μm ((a)–(c) η=1.2 cP, ζ=6 cP, η′=7.6 cP and, (b)–(d) η=1.3 cP, ζ=6 cP, η′=7.7 cP) [64,85].

Download Full Size | PDF

 figure: Fig. 9

Fig. 9 The effects of viscosity on normalized PA wave p(r,t)/p0 vs time (μs), an ultrasonic detector located at r = 500 μm for two different pulse durations (a)–(b) τ = 1 and (c)–(d) 3 ns with different beamwidths σ = 16 (dashed line) and 14 μm (solid line), where R = 16 μm ((a)–(c) η=1.2 cP, ζ=6 cP, η′=7.6 cP and, (b)–(d) η=1.3 cP, ζ=6 cP, η′=7.7 cP) [64,85].

Download Full Size | PDF

4. Results

The integrals J1a, J1b, J2a, and J2b given by Eqs. (34), (35), (43), and (44) are evaluated numerically and the pressure wave is found as a summation of p1 and p2 corresponding to the first and second sources, respectively. However, the contribution coming from the second source is negligible compared to the first one. The pressure waves from the first and second sources can be applied for the suspension of RBCs in an compressible fluid. Our results show that the magnitude of PA signal does not change with different plasma viscosity values as shown in Fig. 8, as expected, in the presence of first and second source terms. Moreover, Fig. 9 shows that the amplitude of PA wave is decreasing with the distance from absorber, r=500 μm when fiber optic sensing systems are considered [79].

The aggregation interaction is described by the Morse potential consisting of a short-range repulsive force when d < r0 and a long-range attractive force for d > r0 [66,86]

E=D(e2β(r0d)2eβ(r0d)).
The corresponding force, F = −∂E/∂r, is obtained from the Morse potential. In our calculations, the energy depth D is used in units of Joule and given in Tables 2 [65,72].

In this paper, the force is approximated with the several parameters involved in the detection of the PA signal, and the immersed boundary method is used to eliminate the effect of the fluid-cell interaction.

Different aggregating conditions are created by changing the surface energy (D), the scaling factor which is related to the thickness of the depletion layer or interactive distance (β), and zero-force length (r0) which are shown in Tables 3 and 4. In these conditions, the aggregation strength is directly related to amount of surface energy, which is expressed by the interaction force between RBCs. The parameters of the Morse potential in Table 3 used in this study were taken from the works presented by Yazdani et al. [65] and Fenech et al. [72], and the ranges of forces shown in Fig. 2(a) were fitted with the experimental data [73]. Moreover, the ranges of forces in Table IV were taken from studies presented by Neu et al. [75] and Steffen et al. [74], as shown in Fig. 2(b). In Fig. 10, the PA pressure wave generated by three sources increases with RBC aggregation (case 1 represents the high aggregation among three cases in Table 3, which is shown in Fig. 2). Moreover, our results demonstrate that high whole-blood viscosity has a role to play in erythrocyte aggregation since the amplitude of PA signal increases when the whole-blood viscosity is higher, as shown in Fig. 10 for case 1. When we compare the three cases, cases 2 and 3 show a lower aggregation. The influences of laser parameters and the levels of RBC aggregation on PA wave are shown in Figs. 11 and 12. These Figs. also show that the short pulse duration results in large wave amplitude, and the amplitude decreases as beamwidth diminishes for these cases. The aggregation for cases 2 and 3 is low and the force in the case 2 is close to the one in case 3. We examine the cases of Dextran 70 and Dextran 150 in Figs. 13 and 14. In Fig. 15, we also analyze the cases 1 and 3 allowing to differentiate and characterize their aggregation levels by observing the PA signal amplitude regarding the chosen force corresponding to the values of function of separation between cell surfaces (β(dr0)) as shown in Fig. 13. Here, the same points (β(dr0)) for each case correspond to various aggregation forces as shown in Fig. 14(d). Our theoretical simulations show that PA signal amplitude increases linearly with increasing aggregation force, which are in excellent agreement with literature data [15,50,88,89]. We use the measured interaction forces for types of Dextran solutions inducing the aggregation in order to validate our analytical approach. Moreover, our results suggest that PA can be used to differentiate red cell aggregation process in detail by using a known interaction force between cells. Firstly, the accuracy of the extended photoacoustic transport model for the characterization of red blood cell morphology in microchannel flow is analyzed with the experimental values in Figs. 1315 by taking into consideration the chosen force values for each case (the cases of Dextran 70 and Dextran 150, case 1 and case 3). Moreover, the solution of the extended photoacoustic wave equation for a Gaussian radial absorption profile make it possible to explicitly observe the effect of laser parameters on the PA wave.

 figure: Fig. 10

Fig. 10 The effects of viscosity on normalized PA wave p(r,t)/p0 generated by three sources for high level of aggregation force (case 1) (dashed line) and non-aggregation force (i.e., without force (wf)) (solid line) vs normalized time cst/R, an ultrasonic detector located at r = 2R, for the same pulse duration (a)–(b) τ = 5 ns with the same beamwidth σ = 8 μm for both cases, where R = 8 μm ((a) η=1.2 cP, ζ=6 mPa.s, η′=7.6 mPa.s and, (b) η=1.2 cP, ζ=20 mPa.s, η′=21.6 mPa.s) [64,85,87].

Download Full Size | PDF

 figure: Fig. 11

Fig. 11 Normalized PA wave p(r,t)/p0 generated by three sources for case 2 (dashed line) and without force (wf) (solid line) vs normalized time cst/R, an ultrasonic detector located at r = 2R, for two different pulse durations (a) τ = 1 and (b) 5 ns with different beamwidths (i) and (ii) represent σ = 6 and 8 μm, respectively; where R = 8 μm (η=1.2 mPa.s, ζ=5 mPa.s, η′=6.6 mPa.s) [64,85].

Download Full Size | PDF

 figure: Fig. 12

Fig. 12 Normalized PA wave p(r,t)/p0 generated by three sources p(r,t)/p0 for case 3 (dashed line) and without force (wf) (solid line) vs normalized time cst/R, an ultrasonic detector located at r = 2R, for two different pulse durations (a) τ = 1 and (b) 5 ns with different beamwidths (i) and (ii) represent σ = 6 and 8 μm, respectively; where R = 8 μm (η=1.2 mPa.s, ζ=4.5 mPa.s, η′=6.1 mPa.s) [64,85].

Download Full Size | PDF

 figure: Fig. 13

Fig. 13 Normalized PA waves p(r,t)/p0 generated by three sources p(r,t)/p0 for without force (solid line), Dextran 150 (dashed line), and Dextran 70 (dashed line) regarding the chosen force at the values of function of between cell surfaces β(dr0) = (a) 0.4, (b) 0.6, (c) 0.8, (d) 1, (e) 1.2, (f) 1.4, (g) 1.6, (h) 1.8 vs normalized time cst/R. Here, an ultrasonic detector is located at r = 2R, or the pulse duration and the beamwidth are τ = 5 ns and σ = 8 μm, and the values of viscosity are η=6.3 mPa.s, ζ=10 mPa.s, η′=18.4 mPa.s for Dextran 70 [74,83,84], and η=6.3 mPa.s, ζ=22.9 mPa.s, η′=31.3 mPa.s for Dextran 150 [74,84], respectively.

Download Full Size | PDF

 figure: Fig. 14

Fig. 14 Normalized PA wave p(r,t)/p0 generated by three sources p(r,t)/p0 for (a) Dextran 70 (14–23 pN) (dashed line), (b) Dextran 150 (43–169 pN) (solid line), (c) both Dextran 70 (dashed line), and Dextran 150 (solid line) vs the chosen force at the values of function of between cell surfaces, (d) aggregation force (F) corresponding to the various aggregation rates vs function of separation between cell surfaces (β(dr0)) for Dextran 70 [74,83,84] (dashed line) and Dextran 150 [74,84] (solid line). Here, an ultrasonic detector is located at r = 2R, or the pulse duration and the beamwidth are τ = 5 ns and σ = 6 μm, and the values of viscosity are η=6.3 mPa.s, ζ=10 mPa.s, η′=18.4 mPa.s for Dextran 70 [83], and η=6.3 mPa.s, ζ=22.9 mPa.s, η′=31.3 mPa.s for Dextran 150 [84], respectively.

Download Full Size | PDF

 figure: Fig. 15

Fig. 15 Normalized PA wave p(r,t)/p0 generated by three sources p(r,t)/p0 for (a) case 1 (solid line), (b) case 3 (dashed line), (c) both case 1 (solid line) and case 3 (dashed line) vs the chosen force values, (d) aggregation force (F) corresponding to the various aggregation rates vs function of separation between cell surfaces (β(dr0)) for case 1 (solid line) and case 3 (dashed line) [65,72]. Here, an ultrasonic detector is located at r = 2R, for the pulse duration and the beamwidth are τ = 5 ns, σ = 8 μm, and the values of viscosity are η=1.2 mPa.s, ζ=6 mPa.s, η′=6.7 mPa.s for case 1, and η=1.2 mPa.s, ζ=4.5 mPa.s, η′=6.1 mPa.s for case 3, respectively [64,85].

Download Full Size | PDF

5. Discussion

The PA imaging may have a great potential for anatomical, functional and molecular imaging of RBCs. In this work, the level of aggregation of RBCs in human blood is assessed and the morphology of blood cells is studied for the detection of RBCs using PA waves obtained analytically. To see the feasibility of the proposed extended photoacoustic transport model including a modified Morse type potential function, an analysis of the amplitude of PA signal is conducted by using the measured aggregation forces [73–75].

We compare our theoretical results with the previous experimental and simulation studies for the PA detection of RBC aggregation and see that our results are in good agreement with the literature [46,47,73–75]. Our numerical results show that the PA signal amplitude increases with the level of aggregation. Some experimental-simulation studies presented that the PA signals could be used to identify the presence of varying degrees of aggregation [15, 50]. However, many other factors such as effects of flow, intervening tissues, ultrasound transducer receiver bandwidth are essential for the experimental confirmation of this study [50]. In order to analyze PA radiofrequency (RF) signals produced by RBC aggregates, Hysi et al. reported the feasibility of detecting these PA RF spectral changes by incorporating a finite transducer in detection of PA signals in his theoretical and experimental study [15]. In our model, the combined Navier-Stokes and PA equation system is solved to find the PA wave by utilizing the immersed boundary method for fluid-structure interaction. Furthermore, our analytical approach shows the effect of the whole blood viscosity on the aggregation processes in the case of third source due to the intercellular interaction force and it also allows to analyze each source separately (If we want to include the interaction force for more than one RBC, then H would be expressed as the summation of the contributions resulted from each RBC.).

In this paper, we solve a combined heat conduction and Navier-Stokes equation system utilizing the Morse-type potential energy function for the characterization of human red cell. The fluid flow containing RBCs in microvessel is modeled by an extended Navier-Stokes equation with the immersed boundary method proposed by Peskin et al. [90]. The immersed boundary method has been utilized to model the flow of RBCs in blood plasma or to describe the blood plasma and RBC membrane interaction between the flow field and deformable cells [59]. We modified the immersed boundary method with respect to the location of PA detector and radius of PA source in order to obtain the PA wave coming from RBC aggregation. Furthermore, our solution makes it possible to observe the effect of laser parameters on the PA wave because the temporal profile is taken as Gaussian rather than a point like Dirac delta function. To validate our method with another one presented by Erkol et al.’s method [62], we also show that the PA signal decreases when the beamwidth decreases and shorter pulse duration leads to a larger wave amplitude as expected. In this regard, adjustment of laser parameters can be very useful for the application of the detection of RBCs.

Another advantage of our method is that it provides comprehensive solutions since the spatiotemporal profile of the laser is taken Gaussian (rather than point source) and RBC aggregation and plasma parameters are taken into consideration. It is well known that blood rheology and viscosity are related to hematocrit (Ht), RBC aggregation, shear induced deformation of RBCs, and plasma viscosity [91–94]. In recent years, several studies have demonstrated that the level of RBC aggregation increases when the plasma fibrinogen concentration increases, which shows the capability of PA for dynamic monitoring of rheological parameters in circulating blood [71,95–97]. Our results show that aggregation is associated with the whole blood plasma viscosity after RBC aggregation because pressure wave amplitude is promoted by the alteration of whole blood viscosity in the case of third source due to the intercellular interaction force. The plasma viscosity may increase up to five-fold in a unfavorable situation ranging from inflammatory diseases to plasma cell dyscrasias [98, 99]. Therefore, the plasma viscosity is significant in specific cases only although this influence is relatively small in general cases [100–102]. For an application, we studied the red blood cell aggregation in a microcirculatory system. Our detailed analytical solution of the extended photoacoustic transport model combined with a modified Morse type potential function accounts for the dynamics of aggregate formation. Hence, the distinctive features of the photoacoustic waves enable to understand diseased or damaged RBCs having abnormal shapes and sizes, which can result from a variety of diseases. Our detailed solution of PA wave to detect RBC aggregation is obtained by solving the combined Navier-Stokes and bio-heat transfer equations. This study also presents the spectral features of the PA signals by considering the interaction between RBCs modeled by the Morse potential. We think that our work can be helpful to improve hybrid simulation approach for not only the characterization of red blood cell morphology but also for cancer cell lines in the microchannel flow. To describe and analyze the mechanical processes inside a microfluidic device, our hybrid model can pave the way toward the development of new physical models in the rapidly advancing field of lab-on-chip technology and photoacoustics. As a future work, in order to analyze the influence of the deformation of the membrane on pressure wave, we will implement the spring network approach beside the Morse potential.

Funding

Bogazici University Research Fund (BAP 15B03TUG3); Republic of Turkey Ministry of Development (2009K120520).

Disclosures

The authors declare that there are no conflicts of interest related to this article.

References and links

1. H. A. Cranston, C. W. Boylan, G. Carroll, S. P. Sutera, J. Williamson, I. Y. Gluzman, and D. J. Krogstad, “Plasmodium falciparum maturation abolishes physiologic red cell deformability,” Science 223, 400–404 (1984). [CrossRef]   [PubMed]  

2. J. P. Shelby, J. White, K. Ganesan, P. K. Rathod, and D. T. Chiu, “A microfluidic model for single-cell capillary obstruction by plasmodium falciparum-infected erythrocytes,” Proc. Natl. Acad. Sci. 100, 14618–14622 (2003). [CrossRef]   [PubMed]  

3. V. M. Ingram, “Gene mutations in human haemoglobin: the chemical difference between normal and sickle cell haemoglobin,” Nature. 180, 326–328 (1957). [CrossRef]   [PubMed]  

4. D. K. Kaul, M. Fabry, P. Windisch, S. Baez, and R. Nagel, “Erythrocytes in sickle cell anemia are heterogeneous in their rheological and hemodynamic characteristics,” J. Clin. Invest. 72, 22 (1983). [CrossRef]   [PubMed]  

5. E. Evans and A. Yeung, “Hidden dynamics in rapid changes of bilayer shape,” Chem. Phys. Lipids 73, 39–56 (1994). [CrossRef]  

6. G. A. Barabino, M. O. Platt, and D. K. Kaul, “Sickle cell biomechanics,” Annu. Rev. Biomed. Eng. 12, 345–367 (2010). [CrossRef]   [PubMed]  

7. E. M. Strohm, E. S. Berndl, and M. C. Kolios, “High frequency label-free photoacoustic microscopy of single cells,” Photoacoustics. 1, 49–53 (2013). [CrossRef]  

8. E. M. Strohm and M. C. Kolios, “Classification of blood cells and tumor cells using label-free ultrasound and photoacoustics,” Cytom. Part A 87, 741–749 (2015). [CrossRef]  

9. G. He, B. Li, and S. Yang, “In vivo imaging of a single erythrocyte with high-resolution photoacoustic microscopy,” Front. Optoelectron. 8, 122–127 (2015). [CrossRef]  

10. T. Feng, Q. Li, C. Zhang, G. Xu, L. J. Guo, J. Yuan, and X. Wang, “Characterizing cellular morphology by photoacoustic spectrum analysis with an ultra-broadband optical ultrasonic detector,” Opt. Express 24, 19853–19862 (2016). [CrossRef]   [PubMed]  

11. A. B. Karpiouk, S. R. Aglyamov, S. Mallidi, J. Shah, W. G. Scott, J. M. Rubin, and S. Y. Emelianov, “Combined ultrasound and photoacoustic imaging to detect and stage deep vein thrombosis: phantom and ex vivo studies,” J. Biomed. Opt. 13, 054061 (2008). [CrossRef]   [PubMed]  

12. M. Rui, W. Bost, E. Weiss, R. Lemor, and M. C. Kolios, “Photoacoustic microscopy and spectroscopy of individual red blood cells,” in Biomedical Optics and 3-D Imaging, OSA Technical Digest (CD) (Optical Society of America, 2010), paper BSuD93. [CrossRef]  

13. E. M. Strohm, E. S. Berndl, and M. C. Kolios, “Probing red blood cell morphology using high-frequency photoacoustics,” Biophys. J. 105, 59–67 (2013). [CrossRef]   [PubMed]  

14. R. J. Talbert, S. H. Holan, and J. A. Viator, “Photoacoustic discrimination of viable and thermally coagulated blood using a two-wavelength method for burn injury monitoring,” Phys. Med. Biol. 52, 1815 (2007). [CrossRef]   [PubMed]  

15. E. Hysi, R. K. Saha, and M. C. Kolios, “On the use of photoacoustics to detect red blood cell aggregation,” Biomed. Opt. Express 3, 2326–2338 (2012). [CrossRef]   [PubMed]  

16. T. Wang, S. Nandy, H. S. Salehi, P. D. Kumavor, and Q. Zhu, “A low-cost photoacoustic microscopy system with a laser diode excitation,” Biomed. Opt. Express 5, 3053–3058 (2014). [CrossRef]   [PubMed]  

17. H. S. Salehi, H. Li, A. Merkulov, P. D. Kumavor, H. Vavadi, M. Sanders, A. Kueck, M. A. Brewer, and Q. Zhu, “Coregistered photoacoustic and ultrasound imaging and classification of ovarian cancer: ex vivo and in vivo studies,” J. Biomed. Opt. 21, 046006 (2016). [CrossRef]  

18. E. Aytac-Kipergil, A. Demirkiran, N. Uluc, S. Yavas, T. Kayikcioglu, S. Salman, S. G. Karamuk, F. O. Ilday, and M. B. Unlu, “Development of a fiber laser with independently adjustable properties for optical resolution photoacoustic microscopy,” Sci. reports 6, 38674 (2016). [CrossRef]  

19. A. Kamruzzahan, F. Kienberger, C. M. Stroh, J. Berg, R. Huss, A. Ebner, R. Zhu, C. Rankl, H. J. Gruber, and P. Hinterdorfer, “Imaging morphological details and pathological differences of red blood cells using tapping-mode afm,” Biol. Chem. 385, 955–960 (2004). [CrossRef]   [PubMed]  

20. I. Dulińska, M. Targosz, W. Strojny, M. Lekka, P. Czuba, W. Balwierz, and M. Szymoński, “Stiffness of normal and pathological erythrocytes studied by means of atomic force microscopy,” J. Biochem. Biophys. Meth. 66, 1–11 (2006). [CrossRef]  

21. M. Fornal, M. Lekka, G. Pyka-Fościak, K. Lebed, T. Grodzicki, B. Wizner, and J. Styczeń, “Erythrocyte stiffness in diabetes mellitus studied with atomic force microscope,” Clin. Hemorheol. Microcirc. 35, 273–276 (2006). [PubMed]  

22. J. L. Maciaszek, B. Andemariam, and G. Lykotrafitis, “Microelasticity of red blood cells in sickle cell disease,” J. Strain Anal. Eng. Des. 46, 368–379 (2011). [CrossRef]  

23. E. A. Evans and P. L. La Celle, “Intrinsic material properties of the erythrocyte membrane indicated by mechanical analysis of deformation,” Blood. 45, 29–43 (1975). [PubMed]  

24. D. E. Discher, D. H. Boal, and S. K. Boey, “Simulations of the erythrocyte cytoskeleton at large deformation. ii. micropipette aspiration,” Biophys. J. 75, 1584–1597 (1998). [CrossRef]   [PubMed]  

25. T. Shiga, N. Maeda, and K. Kon, “Erythrocyte rheology,” Crit. Rev. Oncol. Hematol. 10, 9–48 (1990). [CrossRef]   [PubMed]  

26. R. M. Hochmuth, “Micropipette aspiration of living cells,” J. Biomech. 33, 15–22 (2000). [CrossRef]  

27. S. Hénon, G. Lenormand, A. Richert, and F. Gallet, “A new determination of the shear modulus of the human erythrocyte membrane using optical tweezers,” Biophys. J. 76, 1145–1151 (1999). [CrossRef]   [PubMed]  

28. M. Dao, C. T. Lim, and S. Suresh, “Mechanics of the human red blood cell deformed by optical tweezers,” J. Mech. Phys. Solids 51, 2259–2280 (2003). [CrossRef]  

29. J. Guck, R. Ananthakrishnan, H. Mahmood, T. J. Moon, C. C. Cunningham, and J. Käs, “The optical stretcher: a novel laser tool to micromanipulate cells,” Biophys. J. 81, 767–784 (2001). [CrossRef]   [PubMed]  

30. Y. Z. Yoon, J. Kotar, A. T. Brown, and P. Cicuta, “Red blood cell dynamics: from spontaneous fluctuations to non-linear response,” Soft Matter 7, 2042–2051 (2011). [CrossRef]  

31. D. Kilinc and G. U. Lee, “Advances in magnetic tweezers for single molecule and cell biophysics,” Integr. Biol. 6, 27–34 (2014). [CrossRef]  

32. D. A. Fedosov, B. Caswell, and G. E. Karniadakis, “A multiscale red blood cell model with accurate mechanics, rheology, and dynamics,” Biophys. J. 98, 2215–2225 (2010). [CrossRef]   [PubMed]  

33. J. Li, G. Lykotrafitis, M. Dao, and S. Suresh, “Cytoskeletal dynamics of human erythrocyte,” Proc. Natl. Acad. Sci. 104, 4937–4942 (2007). [CrossRef]   [PubMed]  

34. H. Bow, I. V. Pivkin, M. Diez-Silva, S. J. Goldfless, M. Dao, J. C. Niles, S. Suresh, and J. Han, “A microfabricated deformability based flow cytometer with application to malaria,” Lab Chip. 11, 1065–1073 (2011). [CrossRef]   [PubMed]  

35. M. Diez-Silva, Y. Park, S. Huang, H. Bow, O. Mercereau-Puijalon, G. Deplaine, C. Lavazec, S. Perrot, S. Bonnefoy, M. S. Feld, et al., “Pf155 resa protein influences the dynamic microcirculatory behavior of ring-stage plasmodium falciparum infected red blood cells,” Sci. Rep. 2, 614 (2012). [CrossRef]  

36. C. Dubus and J.-B. Fournier, “A gaussian model for the membrane of red blood cells with cytoskeletal defects,” Eur. Lett. 75, 181 (2006). [CrossRef]  

37. E. M. Strohm, I. Gorelikov, N. Matsuura, and M. C. Kolios, “Modeling photoacoustic spectral features of micron-sized particles,” Phys. Med. Biol. 59, 5795 (2014). [CrossRef]   [PubMed]  

38. R. K. Saha, S. Karmakar, A. Adhikari, and M. C. Kolios, “Photoacoustic field calculation for nonspherical axisymmetric fluid particles,” Biomed. Phys. Eng. Express 3, 015017 (2017). [CrossRef]  

39. M. Musielak, “Red blood cell-deformability measurement: review of techniques,” Clin. Hemorheol. Microcirc. 42, 47–64 (2009). [PubMed]  

40. F. Rico, P. Roca-Cusachs, N. Gavara, R. Farré, M. Rotger, and D. Navajas, “Probing mechanical properties of living cells by atomic force microscopy with blunted pyramidal cantilever tips,” Phys. Rev. E 72, 021914 (2005). [CrossRef]  

41. A. R. Bausch, W. Möller, and E. Sackmann, “Measurement of local viscoelasticity and forces in living cells by magnetic tweezers,” Biophys. J. 76, 573–579 (1999). [CrossRef]   [PubMed]  

42. W. Song, W. Zheng, R. Liu, R. Lin, H. Huang, X. Gong, S. Yang, R. Zhang, and L. Song, “Reflection-mode in vivo photoacoustic microscopy with subwavelength lateral resolution,” Biomed. Opt. Exp. 5, 4235–4241 (2014). [CrossRef]  

43. E. M. Strohm, M. J. Moore, and M. C. Kolios, “Single cell photoacoustic microscopy: a review,” IEEE J. Sel. Top. Quantum Electron. 22, 137–151 (2016). [CrossRef]  

44. D. Biswas, S. Vasudevan, G. C. Chen, P. Bhagat, N. Sharma, and S. Phatak, “Time–frequency based photoacoustic spectral response technique for differentiating human breast masses,” Biomed. Phys. Eng. Express 3, 035002 (2017). [CrossRef]  

45. R. K. Saha, S. Karmakar, and M. Roy, “Photoacoustic response of suspended and hemolyzed red blood cells,” Appl. Phys. Lett. 103, 044101 (2013). [CrossRef]  

46. R. K. Saha, S. Karmakar, and M. Roy, “Computational investigation on the photoacoustics of malaria infected red blood cells,” PLoS One 7, e51774 (2012). [CrossRef]   [PubMed]  

47. R. K. Saha and M. C. Kolios, “Effects of erythrocyte oxygenation on optoacoustic signals,” J. Biomed. Opt. 16, 115003 (2011). [CrossRef]   [PubMed]  

48. G. Diebold, “Photoacoustic monopole radiation: waves from objects with symmetry in one, two and three dimensions,” Photoacoust. imaging spectroscopy 144, 3–17 (2009). [CrossRef]  

49. E. Hysi, R. K. Saha, and M. C. Kolios, “Characterization of red blood cell aggregation with photoacoustics: A theoretical and experimental study,” in “Proc. IUS,” (2011), pp. 1187–1190.

50. R. K. Saha and M. C. Kolios, “A simulation study on photoacoustic signals from red blood cells,” J. Acoust. Soc. Am. 129, 2935–2943 (2011). [CrossRef]   [PubMed]  

51. R. P. Solano, F. I. Ramirez-Perez, J. A. Castorena-Gonzalez, E. A. Anell, G. Gutiérrez-Juárez, and L. Polo-Parada, “An experimental and theoretical approach to the study of the photoacoustic signal produced by cancer cells,” AIP Adv. 2, 011102 (2012). [CrossRef]  

52. Y. Li, H. Fang, C. Min, and X. Yuan, “Analytic theory of photoacoustic wave generation from a spheroidal droplet,” Opt. Exp. 22, 19953–19969 (2014). [CrossRef]  

53. Y. Liu and W. K. Liu, “Rheology of red blood cell aggregation by computer simulation,” J. Comput. Phys. 220, 139–154 (2006). [CrossRef]  

54. R. A. Kruger, P. Liu, Y. Fang, C. R. Appledorn, et al., “Photoacoustic ultrasound (paus)–reconstruction tomography,” Med. physics 22, 1605–1609 (1995). [CrossRef]  

55. L. V. Wang, “Tutorial on photoacoustic microscopy and computed tomography,” IEEE J. Sel. Top. Quantum Electron. 14, 171–179 (2008). [CrossRef]  

56. L. Wang and H.-i. Wu, Biomedical Optics: Principles and Imaging (Wiley, 2007).

57. A. R. Fisher, A. J. Schissler, and J. C. Schotland, “Photoacoustic effect for multiply scattered light,” Phys. Rev. E 76, 036604 (2007). [CrossRef]  

58. T. Wang, U. Rongin, and Z. Xing, “A micro-scale simulation of red blood cell passage through symmetric and asymmetric bifurcated vessels,” Sci. Rep. 6, 20262 (2016).

59. J. Zhang, P. C. Johnson, and A. S. Popel, “An immersed boundary lattice boltzmann approach to simulate deformable liquid capsules and its application to microscopic blood flows,” Phys. Biol. 4, 285 (2007). [CrossRef]  

60. P. M. Morse and H. Feshbach, Methods of Theoretical Physics (Technology Press, 1946).

61. L. V. Wang and H.-i. Wu, Biomedical Optics: Principles and Imaging (John Wiley & Sons, 2012).

62. H. Erkol, E. Aytac-Kipergil, and M. B. Unlu, “Photoacoustic radiation force on a microbubble,” Phys. Rev. E 90, 023001 (2014). [CrossRef]  

63. C. S. Peskin, “Numerical analysis of blood flow in the heart,” J. Comput. Phys. 25, 220–252 (1977). [CrossRef]  

64. J. Zhang, P. C. Johnson, and A. S. Popel, “Effects of erythrocyte deformability and aggregation on the cell free layer and apparent viscosity of microscopic blood flows,” Microvasc. Res. 77, 265–272 (2009). [CrossRef]   [PubMed]  

65. A. Yazdani, H. Li, J. D. Humphrey, and G. E. Karniadakis, “A general shear-dependent model for thrombus formation,” PLOS Comput. Biol. 13, e1005291 (2017). [CrossRef]   [PubMed]  

66. Y. Liu, L. Zhang, X. Wang, and W. K. Liu, “Coupling of navier–stokes equations with protein molecular dynamics and its application to hemodynamics,” Int. J. Numer. Methods Fluids 46, 1237–1252 (2004). [CrossRef]  

67. L. Xiao, Y. Liu, S. Chen, and B. Fu, “Simulation of deformation and aggregation of two red blood cells in a stenosed microvessel by dissipative particle dynamics,” Cell Biochem. Biophys. 74, 513–525 (2016). [CrossRef]   [PubMed]  

68. J. Zhang, P. C. Johnson, and A. S. Popel, “Red blood cell aggregation and dissociation in shear flows simulated by lattice boltzmann method,” J. Biomech. 41, 47–55 (2008). [CrossRef]  

69. K.-i. Tsubuto, S. Wada, and T. Yamaguchi, “Simulation study on effects of hematocrit on blood flow properties using particle method,” J. Biomech. Sci. Eng. 1, 159–170 (2006). [CrossRef]  

70. T. Ye, N. Phan-Thien, B. C. Khoo, and C. T. Lim, “Dissipative particle dynamics simulations of deformation and aggregation of healthy and diseased red blood cells in a tube flow,” Phys. Fluids 26, 111902 (2014). [CrossRef]  

71. G. Késmárky, P. Kenyeres, M. Rábai, and K. Tóth, “Plasma viscosity: a forgotten variable,” Clin. Hemorheol. Microcirc. 39, 243–246 (2008). [PubMed]  

72. M. Fenech, D. Garcia, H. J. Meiselman, and G. Cloutier, “A particle dynamic model of red blood cell aggregation kinetics,” Ann. Biomed. Eng 37, 2299–2309 (2009). [CrossRef]   [PubMed]  

73. A. Y. Maklygin, A. V. Priezzhev, A. Karmenian, S. Y. Nikitin, I. Obolenskii, A. E. Lugovtsov, and K. Li, “Measurement of interaction forces between red blood cells in aggregates by optical tweezers,” Quantum Electron. 42, 500 (2012). [CrossRef]  

74. P. Steffen, C. Verdier, and C. Wagner, “Quantification of depletion-induced adhesion of red blood cells,” Phys. review letters 110, 018102 (2013). [CrossRef]  

75. B. Neu and H. J. Meiselman, “Depletion-mediated red blood cell aggregation in polymer solutions,” Biophys. journal 83, 2482–2490 (2002). [CrossRef]  

76. M. Abramowitz and I. A. Stegun, Handbook of Mathematical Functions: With Formulas, Graphs, and Mathematical Tables, vol. 55 (Courier Corporation, 1964).

77. G. B. Arfken, H. J. Weber, and F. E. Harris, Mathematical Methods for Physicists: A Comprehensive Guide (Academic Press, 2011).

78. E. M. Strohm, E. Hysi, and M. C. Kolios, “Photoacoustic measurements of single red blood cells,” in “Proc. IUS” (2012), pp. 1406–1409.

79. X. Bai, Y. Liang, H. Sun, L. Jin, J. Ma, B.-O. Guan, and L. Wang, “Sensitivity characteristics of broadband fiber-laser-based ultrasound sensors for photoacoustic microscopy,” Opt. express 25, 17616–17626 (2017). [CrossRef]   [PubMed]  

80. A. Demirkiran, A. Karakuzu, H. Erkol, H. Torun, and M. B. Unlu, “Analysis of microcantilevers excited by pulsed-laser-induced photoacoustic waves,” Opt. express 26, 4906–4919 (2018). [CrossRef]   [PubMed]  

81. A. Ohlinger, A. Deak, A. A. Lutich, and J. Feldmann, “Optically trapped gold nanoparticle enables listening at the microscale,” Phys. review letters 108, 018101 (2012). [CrossRef]  

82. Y. Park, C. A. Best, K. Badizadegan, R. R. Dasari, M. S. Feld, T. Kuriabova, M. L. Henle, A. J. Levine, and G. Popescu, “Measurement of red blood cell mechanics during morphological changes,” Proc. Natl. Acad. Sci. 107, 6731–6736 (2010). [CrossRef]   [PubMed]  

83. M. Brust, O. Aouane, M. Thiébaud, D. Flormann, C. Verdier, L. Kaestner, M. Laschke, H. Selmi, A. Benyoussef, T. Podgorski, et al., “The plasma protein fibrinogen stabilizes clusters of red blood cells in microcapillary flows,” Sci. reports 4, 4348 (2014). [CrossRef]  

84. A. B. Goins, H. Sanabria, and M. N. Waxham, “Macromolecular crowding and size effects on probe microviscosity,” Biophys. journal 95, 5362–5373 (2008). [CrossRef]  

85. A. G. Tsai, B. Y. Salazar Vázquez, P. Cabrales, E. B. Kistler, D. M. Tartakovsky, S. Subramaniam, S. A. Acharya, and M. Intaglietta, “Replacing the transfusion of 1–2 units of blood with plasma expanders that increase oxygen delivery capacity: Evidence from experimental studies,” J. functional biomaterials 5, 232–245 (2014). [CrossRef]  

86. S. Flügge, Practical Quantum Mechanics (Springer Science & Business Media, 2012).

87. G. Nash, “Blood rheology and ischaemia,” Eye 5, 151 (1991). [CrossRef]   [PubMed]  

88. E. Hysi, R. K. Saha, and M. C. Kolios, “Photoacoustic ultrasound spectroscopy for assessing red blood cell aggregation and oxygenation,” J. Biomed. Opt. 17, 125006 (2012). [CrossRef]   [PubMed]  

89. C. L. Bayer, S. Y. Nam, Y.-S. Chen, and S. Y. Emelianov, “Photoacoustic signal amplification through plasmonic nanoparticle aggregation,” J. Biomed. Opt. 18, 016001 (2013). [CrossRef]  

90. C. S. Peskin, “Flow patterns around heart valves: a numerical method,” J. Comput. Phys. 10, 252–271 (1972). [CrossRef]  

91. G. Lowe, “1 blood rheology in vitro and in vivo,” Baillière’s Clin. Haematol. 1, 597–636 (1987). [CrossRef]  

92. H. H. Lipowsky, “Microvascular rheology and hemodynamics,” Microcirculation. 12, 5–15 (2005). [CrossRef]   [PubMed]  

93. L. Dintenfass, “Blood rheology in cardio-vascular diseases,” Nature. 199, 813–815 (1963). [CrossRef]   [PubMed]  

94. H. Schmid-Schönbein, “Blood rheology and physiology of microcirculation,” Ric. Clin. Lab. 11, 13–33 (1980).

95. O. K. Baskurt and H. J. Meiselman, “Blood rheology and hemodynamics,” “Proc Thromb. Hemost. ” 29, 435–450 (2003). [CrossRef]  

96. M. J. Simmonds, H. J. Meiselman, and O. K. Baskurt, “Blood rheology and aging,” JGC 10, 291 (2013). [PubMed]  

97. H. C. Kwaan, “Role of plasma proteins in whole blood viscosity: a brief clinical review,” Clin. Hemorheol. Microcirc. 44, 167–176 (2010). [PubMed]  

98. F. Neumann, H. Katus, E. Hoberg, P. Roebruck, M. Braun, H. Haupt, H. Tillmanns, and W. Kübler, “Increased plasma viscosity and erythrocyte aggregation: indicators of an unfavourable clinical outcome in patients with unstable angina pectoris,” Heart. 66, 425–430 (1991). [CrossRef]  

99. H. C. Kwaan and A. Bongu, “The hyperviscosity syndromes,” in Seminars in Thrombosis and Hemostasis, vol. 25 (Thieme Medical Publishers, 1999), pp. 199–208. [CrossRef]  

100. T. Somer, “4 rheology of paraproteinaemias and the plasma hyperviscosity syndrome,” Baillière’s Clin. Haematol. 1, 695–723 (1987). [CrossRef]  

101. T. Somer and H. J. Meiselman, “Disorders of blood viscosity,” Ann. Med. 25, 31–39 (1993). [CrossRef]   [PubMed]  

102. S. Chien, J. A. Dormandy, E. Ernst, and A. Matrai, Clinical Hemorheology: Applications in Cardiovascular and Hematological Disease, Diabetes, Surgery and Gynecology (Springer Science & Business Media, 2012).

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (15)

Fig. 1
Fig. 1 The schematic of the model.
Fig. 2
Fig. 2 Aggregation force (F) corresponding to the various aggregation rates vs function of separation between cell surfaces (β(d−r0)) for (a) case 1 [65, 72]: D = 3 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 3 μm; case 2 [65, 72]: D = 2.1 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 2.5 μm; case 3 [65, 72]: D = 2.1 × 10−17 J/m2, β = 6 × 105 m−1, r0 = 2 μm, (b) Dextran 70 [74]: D = 5.75 × 10−17 J/m2, β = 6 × 105 m−1, r0 = 2 μm; Dextran 150 [74]: D = 56.4 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 3 μm.
Fig. 3
Fig. 3 Normalized ∇·F (modified aggregation forces) vs function of separation between cell surfaces (β(d−r0)) for case 1 [65, 72]: D = 3 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 3 μm; case 2 [65,72]: D = 2.1 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 2.5 μm; case 3 [65,72]: D = 2.1 × 10−17 J/m2, β = 6 × 105 m−1, r0 = 2 μm.
Fig. 4
Fig. 4 Normalized ∇·F which represents the different red blood cell aggregation conditions with different intercellular strengths vs time scale of acoustic wave, t(s) for case 1 [65,72]: D = 3 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 3 μm; case 2 [65,72]: D = 2.1 × 10−17 J/m2, β = 8 × 105 m−1, r0 = 2.5 μm; case 3 [65, 72]: D = 2.1 × 10−17 J/m2, β = 6 × 105 m−1, r0 = 2 μm.
Fig. 5
Fig. 5 Normalized PA wave p(r,t)/p0 generated by first source vs normalized time cst/R, an ultrasonic detector located at position r = 2R for the two different pulse durations (a) τ = 1 and (b) 5 ns with different beamwidths σ = 6 μm (dashed line) and 8 μm (solid line), where R = 8 μm.
Fig. 6
Fig. 6 Normalized power spectral density of the photoacoustic wave in Fig. 5, an ultrasonic detector located at the position r = 2R for the two different pulse durations (a) τ = 1 and (b) 5 ns with the different beamwidths σ = 6 μm (dashed line) and 8 μm (solid line), where R = 8 μm.
Fig. 7
Fig. 7 Normalized PA wave p(r,t)/p0 generated by first source vs time time (μs), an ultrasonic detector located at position r = 2 mm for the two different pulse durations (a) τ = 1 with different beamwidths σ = 8 μm (dashed line) and 6 μm (solid line), where R = 8 μm and (b) 5 ns with different beamwidths σ = 8 μm (dashed line) and 6 μm (solid line), respectively where R = 8 μm.
Fig. 8
Fig. 8 The effects of viscosity on normalized PA wave p(r,t)/p0 vs normalized time cst/R, an ultrasonic detector located at r = 2R for two different pulse durations (a)–(b) τ = 1, (c)–(d) 5 ns with different beamwidths σ = 6 (dashed line) and 8 μm (solid line), where R = 8 μm ((a)–(c) η=1.2 cP, ζ=6 cP, η′=7.6 cP and, (b)–(d) η=1.3 cP, ζ=6 cP, η′=7.7 cP) [64,85].
Fig. 9
Fig. 9 The effects of viscosity on normalized PA wave p(r,t)/p0 vs time (μs), an ultrasonic detector located at r = 500 μm for two different pulse durations (a)–(b) τ = 1 and (c)–(d) 3 ns with different beamwidths σ = 16 (dashed line) and 14 μm (solid line), where R = 16 μm ((a)–(c) η=1.2 cP, ζ=6 cP, η′=7.6 cP and, (b)–(d) η=1.3 cP, ζ=6 cP, η′=7.7 cP) [64,85].
Fig. 10
Fig. 10 The effects of viscosity on normalized PA wave p(r,t)/p0 generated by three sources for high level of aggregation force (case 1) (dashed line) and non-aggregation force (i.e., without force (wf)) (solid line) vs normalized time cst/R, an ultrasonic detector located at r = 2R, for the same pulse duration (a)–(b) τ = 5 ns with the same beamwidth σ = 8 μm for both cases, where R = 8 μm ((a) η=1.2 cP, ζ=6 mPa.s, η′=7.6 mPa.s and, (b) η=1.2 cP, ζ=20 mPa.s, η′=21.6 mPa.s) [64,85,87].
Fig. 11
Fig. 11 Normalized PA wave p(r,t)/p0 generated by three sources for case 2 (dashed line) and without force (wf) (solid line) vs normalized time cst/R, an ultrasonic detector located at r = 2R, for two different pulse durations (a) τ = 1 and (b) 5 ns with different beamwidths (i) and (ii) represent σ = 6 and 8 μm, respectively; where R = 8 μm (η=1.2 mPa.s, ζ=5 mPa.s, η′=6.6 mPa.s) [64,85].
Fig. 12
Fig. 12 Normalized PA wave p(r,t)/p0 generated by three sources p(r,t)/p0 for case 3 (dashed line) and without force (wf) (solid line) vs normalized time cst/R, an ultrasonic detector located at r = 2R, for two different pulse durations (a) τ = 1 and (b) 5 ns with different beamwidths (i) and (ii) represent σ = 6 and 8 μm, respectively; where R = 8 μm (η=1.2 mPa.s, ζ=4.5 mPa.s, η′=6.1 mPa.s) [64,85].
Fig. 13
Fig. 13 Normalized PA waves p(r,t)/p0 generated by three sources p(r,t)/p0 for without force (solid line), Dextran 150 (dashed line), and Dextran 70 (dashed line) regarding the chosen force at the values of function of between cell surfaces β(dr0) = (a) 0.4, (b) 0.6, (c) 0.8, (d) 1, (e) 1.2, (f) 1.4, (g) 1.6, (h) 1.8 vs normalized time cst/R. Here, an ultrasonic detector is located at r = 2R, or the pulse duration and the beamwidth are τ = 5 ns and σ = 8 μm, and the values of viscosity are η=6.3 mPa.s, ζ=10 mPa.s, η′=18.4 mPa.s for Dextran 70 [74,83,84], and η=6.3 mPa.s, ζ=22.9 mPa.s, η′=31.3 mPa.s for Dextran 150 [74,84], respectively.
Fig. 14
Fig. 14 Normalized PA wave p(r,t)/p0 generated by three sources p(r,t)/p0 for (a) Dextran 70 (14–23 pN) (dashed line), (b) Dextran 150 (43–169 pN) (solid line), (c) both Dextran 70 (dashed line), and Dextran 150 (solid line) vs the chosen force at the values of function of between cell surfaces, (d) aggregation force (F) corresponding to the various aggregation rates vs function of separation between cell surfaces (β(dr0)) for Dextran 70 [74,83,84] (dashed line) and Dextran 150 [74,84] (solid line). Here, an ultrasonic detector is located at r = 2R, or the pulse duration and the beamwidth are τ = 5 ns and σ = 6 μm, and the values of viscosity are η=6.3 mPa.s, ζ=10 mPa.s, η′=18.4 mPa.s for Dextran 70 [83], and η=6.3 mPa.s, ζ=22.9 mPa.s, η′=31.3 mPa.s for Dextran 150 [84], respectively.
Fig. 15
Fig. 15 Normalized PA wave p(r,t)/p0 generated by three sources p(r,t)/p0 for (a) case 1 (solid line), (b) case 3 (dashed line), (c) both case 1 (solid line) and case 3 (dashed line) vs the chosen force values, (d) aggregation force (F) corresponding to the various aggregation rates vs function of separation between cell surfaces (β(dr0)) for case 1 (solid line) and case 3 (dashed line) [65,72]. Here, an ultrasonic detector is located at r = 2R, for the pulse duration and the beamwidth are τ = 5 ns, σ = 8 μm, and the values of viscosity are η=1.2 mPa.s, ζ=6 mPa.s, η′=6.7 mPa.s for case 1, and η=1.2 mPa.s, ζ=4.5 mPa.s, η′=6.1 mPa.s for case 3, respectively [64,85].

Tables (4)

Tables Icon

Table 1 Model parameters [67,68,70].

Tables Icon

Table 2 Model parameters [65,72].

Tables Icon

Table 3 Constitutive parameters for the three various forces resulting from the RBC aggregation [65,72,73].

Tables Icon

Table 4 The model parameters for the measured dextran-induced aggregation forces of red blood cells [74].

Equations (51)

Equations on this page are rendered with MathJax. Learn more.

ρ 0 c p T ( r , t ) t κ 2 T ( r , t ) = H ( r , t )
ρ t + ( ρ v ) = ρ β T ( r , t ) t
ρ [ v t + v ( v ) ] = p + η 2 v + ( ζ + 1 / 3 η ) ( v )
ρ t + ρ v = β H ( r , t ) c p .
δ ρ t + ρ 0 v = β H ( r , t ) c p
ρ 0 v t = δ p + η 2 v + ( ζ + 1 3 η ) ( v ) .
ρ 0 v t = δ p + η 2 v + ν ( v ) + f ( r , t ) ,
f ( r , t ) = n = 1 N [ F n Δ ( r Y n ( t ) ) ]
1 c s 2 2 p ( r , t ) t 2 = 2 p ( r , t ) + η ρ 0 c s 2 [ 2 p ( r , t ) t Γ 2 H ( r , t ) ] f ( r , t ) + β c p H ( r , t ) t
2 p ( r , t ) + η ρ 0 c s 2 2 p ( r , t ) t 1 c s 2 2 p ( r , t ) t 2 = S ( r , t )
S ( r , t ) = β c p H ( r , t ) t + Γ η ρ c s 2 2 H ( r , t ) + f ( r , t ) .
2 p ˜ ( r , ω ) + ω 2 p ˜ ( r , ω ) c s 2 ( 1 i ω B ) = S ˜ ( r , ω ) .
G ˜ ( r , r ; ω ) = 1 4 π | r r | exp ( i k 1 | r r | )
H ( r , t ) = A ( r ) I ( t ) .
A ( r ) = p 0 ( r ) c p c s 2 β .
p 0 ( r ) = β T ( r ) c κ
I ( t ) = exp ( t 2 / 2 τ 2 ) 2 π τ 2
S 1 ( r , t ) = p 0 ( r ) c s 2 t [ exp ( t 2 / 2 τ 2 ) 2 π τ 2 ] = 1 2 π τ 3 p 0 ( r ) c s 2 t exp ( t 2 / 2 τ 2 ) .
S ˜ 1 ( r , ω ) = 1 2 π τ 3 p 0 ( r ) c s 2 + t exp ( t 2 / 2 τ 2 ) exp ( i ω t ) d t = p 0 ( r ) i ω c s 2 exp ( τ 2 ω 2 / 2 ) .
S 2 ( r , t ) = η T ρ 0 c s 2 [ exp ( t 2 / 2 τ 2 ) 2 π τ 2 ] 2 p 0 ( r ) .
S ˜ 2 ( r , ω ) = η Γ ρ c s 2 2 p 0 ˜ ( r ) + exp ( t 2 / 2 τ 2 ) 2 π τ 2 exp ( i ω t ) d t = η Γ ρ c s 2 2 p 0 ˜ ( r ) exp ( τ 2 ω 2 / 2 ) .
f ( r , t ) = n = 1 N [ F n Δ ( r Y n ( t ) ) ]
Δ ( X ) = ( 2 π h 2 ) 3 / 2 exp [ ( r r ) 2 2 h 2 ] exp ( t 2 / 2 τ 2 ) 2 π
f ( r , t ) = 2 β D ( e 2 β ( r 0 d ) e β ( r 0 d ) ) ( 2 π h 2 ) 3 / 2 exp [ ( r r ) 2 2 h 2 ] exp ( t 2 / 2 τ 2 ) 2 π
p 0 ( r ) = p 0 exp ( r 2 2 σ 2 ) θ ( r ) θ ( r + R )
p ˜ ( r , ω ) = G ˜ ( r , r ; ω ) S ˜ ( r , ω ) d 3 r
p 1 ˜ ( r , ω ) = i p 0 4 π ω c s 2 exp ( τ 2 ω 2 2 ) 0 2 π d ϕ 0 R ( r ) 2 d r 1 + 1 exp [ i k 1 | r r | ] | r r | d μ
1 + 1 exp [ ( i k 1 ) ( r 2 + r 2 2 r r μ ) ] ( r 2 + r 2 2 r r μ ) d μ = 1 i r r k 1 [ exp [ i k 1 ( r r ) ] exp [ i k 1 ( r + r ) ] ] .
p 1 ( r , t ) = p 0 2 2 π r c s 2 0 R d r r exp ( r 2 2 σ 2 ) × exp [ τ 2 ω 2 2 + i k 1 ( r ± r ) i ω t ] [ c s 1 i ω B ω ] ω d ω ,
1 i ω B = 1 i B ω 2 + 1 8 ( B ω ) 2 + O ( ( B ω ) 3 ) ,
I = exp [ τ 2 ω 2 2 + ( i ω ( r ± r ) c s 1 i ω B ) i ω t ] d ω i B 2 ω exp [ τ 2 ω 2 2 + ( i ω ( r ± r ) c s 1 i ω B ) i ω t ] d ω .
exp [ i ω ( r ± r ) c s 1 i ω B ] ~ exp [ i ω ( r ± r ) c s ] B ω [ ω ( r ± r ) e i ω ( r ± r ) c s ] 2 c s .
p 1 ( r , t ) = p 0 2 2 π 1 r c s 0 R d r r exp ( r 2 2 σ 2 ) × { exp [ τ 2 ω 2 2 + ( i ω ( r ± r ) c s ) i ω t ] d ω i B 2 ω exp [ τ 2 ω 2 2 + ( i ω ( r ± r ) c s ) i ω t ] d ω } .
p 1 ( r , t ) = [ p 0 2 2 π 1 r c s ] [ J 1 a + i B 2 J 1 b ]
J 1 a = 0 R d r r exp ( r 2 2 σ 2 ) [ 2 π exp ( ( c s t + r r ) 2 2 τ 2 c s 2 ) τ 2 π exp ( ( c s t + r r ) 2 2 τ 2 c s 2 ) τ ]
J 1 b = 0 R d r r exp ( r 2 2 σ 2 ) [ i 2 π ( c s t + r + r ) exp ( ( c s t + r + r ) 2 2 τ 2 c s 2 ) τ 3 c s + i 2 π ( c s t + r r ) exp ( ( c s t + r r ) 2 2 τ 2 c s 2 ) τ 3 c s ] .
J 1 a = τ σ 2 c s 2 ( σ 2 + τ 2 c s 2 ) 3 / 2 exp [ 2 R ( r c s t ) + 2 ( r c s t ) 2 + R 2 2 τ 2 c s 2 R 2 2 σ 2 ] ( 2 π σ ( r c s t ) { erf [ σ 2 ( r + R + c s t ) + R τ 2 c s 2 2 τ σ c s σ 2 + τ 2 c s 2 ] × exp [ ( r + R c s t ) 2 2 τ 2 c s 2 + σ 2 ( r c s t ) 2 2 τ 2 c s 2 ( σ 2 + τ 2 c s 2 ) + R 2 2 σ 2 ] + erf [ σ 2 ( r + R c s t ) + R τ 2 c s 2 2 τ σ c s σ 2 + τ 2 c s 2 ] exp [ ( σ 2 ( r + R c s t ) + R τ 2 c s 2 ) 2 σ 2 ( σ 2 + τ 2 c s 2 ) + ( r c s t ) 2 2 τ 2 c s 2 ] ] 2 τ c s σ 2 + τ 2 c s 2 exp [ ( r c s t ) 2 2 τ 2 c s 2 ] exp [ 2 R ( r c s t ) τ 2 c s 2 ] 1 } ) × θ ( r | R c s t | ) θ ( r + R + c s t )
p 2 ( r , t ) = η T i ρ c s 2 0 R r d r 2 p 0 ( r ) × exp [ τ 2 ω 2 2 + i k 1 ( r ± r ) i ω t ] [ c s 1 i ω B ω ] d ω .
p 2 ( r , t ) = η Γ i ρ c s 0 R r d r 2 p 0 ( r ) × { exp [ τ 2 ω 2 2 + i ω ( r ± r ) c s i ω t ] ω d ω i B 2 exp [ τ 2 ω 2 2 + i ω ( r ± r ) c s i ω t ] d ω } .
J = exp [ τ 2 z 2 2 + i z ( r ± R ) c s i z t ] z d z ,
J = { π i lim z 0 z exp [ τ 2 z 2 2 + i z ( ( r ± R ) c s t ) ] z if ( r ± R c s t ) > 0 π i lim z 0 z exp [ τ 2 z 2 2 + i z ( r ± R c s t ) ] z if ( r ± R c s t ) < 0 .
p 2 ( r , t ) = B η Γ p 0 4 2 π ρ r c s 0 R d r r [ r 2 exp ( r 2 2 σ 2 ) σ 4 exp ( r 2 2 σ 2 ) σ 2 ] × [ 2 π exp [ ( c s t + r + r ) 2 2 τ 2 c s 2 ] τ 2 π exp [ ( c s t + r r ) 2 2 τ 2 c s 2 ] τ ] .
p 2 ( r , t ) = [ B η Γ p 0 4 2 π ρ r c s ] ( J 2 a J 2 b )
J 2 a = 0 R d r r [ ( r ) 2 exp ( r 2 2 σ 2 ) σ 4 exp ( r 2 2 σ 2 ) σ 2 ] × [ 2 π exp [ ( c s t + r r ) 2 2 τ 2 c s 2 ] τ ]
J 2 b = 0 R d r r [ ( r ) 2 exp ( r 2 2 σ 2 ) σ 4 exp ( r 2 2 σ 2 ) σ 2 ] × [ 2 π exp [ ( c s t + r r ) 2 2 τ 2 c s 2 ] τ ] .
p 3 ( r , t ) = c s τ 4 i 2 π r 0 R r d r f ( r , ω ) × { exp [ τ 2 ω 2 2 + i ω ( r ± r ) c s i ω t ] ω d ω i B 2 exp [ τ 2 ω 2 2 + i ω ( r ± r ) c s i ω t ] d ω } .
p 3 ( r , t ) = c s τ B 4 2 π r ( J 3 a J 3 b )
J 3 a = β D [ e 2 β ( r 0 d ) e β ( r 0 d ) ] π h 5 0 R d r r ( r r ) exp [ ( r r ) 2 2 h 2 ] × [ 2 π exp [ ( c s t + r + r ) 2 2 τ 2 c s 2 ] τ ]
J 3 b = β D [ e 2 β ( r 0 d ) e β ( r 0 d ) ] π h 5 0 R d r r ( r r ) exp [ ( r r ) 2 2 h 2 ] × [ 2 π exp [ ( c s t + r r ) 2 2 τ 2 c s 2 ] τ ] .
J 3 a = β D ( e β ( r 0 d ) 1 ) π τ h 5 × { τ h 2 c s 2 ( τ 2 c s 2 + h 2 ) 5 / 2 exp [ r ( r t c s ) τ 2 c s 2 + h 2 r 2 c s 2 + t 2 2 τ 2 + β ( r 0 d ) r 2 2 h 2 ] × [ 2 τ h 2 c s τ 2 c s 2 + h 2 ( t c s 2 r ) exp [ τ 2 r 2 c s + h 2 r t τ 4 c s 3 + τ 2 h 2 c s ] + exp ( τ 4 r 2 c s 4 + 2 τ 2 h 2 r t c s 3 + h 4 r 2 + h 4 t 2 c s 2 2 τ 4 h 2 c s 4 + 2 τ 2 h 4 c s 2 ) 2 π h × ( h 2 ( c s 2 ( τ 2 + t 2 ) + 2 r 2 3 r t c s ) + τ 2 c s 2 ( τ 2 c s 2 2 r 2 + r t c s ) ) × erf [ τ 2 r c s 2 h 2 ( r t c s ) 2 τ h c s τ 2 c s 2 + h 2 ] ] τ h 2 c s 2 ( τ 2 c s 2 + h 2 ) 5 / 2 exp [ r ( r t c s ) τ 2 c s 2 + h 2 r 2 + R 2 + t 2 c s 2 2 b 2 c s 2 + β ( r 0 d ) r 2 + R 2 2 h 2 ] × ( 2 τ c s τ 2 c s 2 + h 2 ( τ 2 R c s 2 + h 2 ( 2 r + R + t c s ) ) × exp ( r ( r t c s ) τ 2 c s 2 + h 2 + t c s ( r + R ) r R τ 2 c s 2 + r R h 2 ) + exp [ τ 4 c s 4 ( r 2 + R 2 ) + 2 τ 2 h 2 c s 2 ( r t c s + R 2 ) + h 4 ( r 2 + R 2 + t 2 c s 2 ) 2 τ 2 h 2 c s 2 ( τ 2 c s 2 + h 2 ) ] × 2 π h ( h 2 ( c s 2 ( τ 2 + t 2 ) + 2 r 2 3 r t c s ) + τ 2 c s 2 ( τ 2 c s 2 2 r 2 + r t c s ) ) × erf [ τ 2 c s 2 ( r R ) h 2 ( r + R t c s ) 2 τ h c s τ 2 c s 2 + h 2 ] ) θ ( r | R c s t | ) θ ( r + R + c s t ) } .
E = D ( e 2 β ( r 0 d ) 2 e β ( r 0 d ) ) .
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.