First-Order Individual Gas Sensors as Next Generation Reliable Analytical Instruments

Not Accessible

Your library or personal account may give you access

Abstract

It is conventionally expected that the performance of existing gas sensors may degrade in the field compared to laboratory conditions because (i) a sensor may lose its accuracy in the presence of chemical interferences and (ii) variations of ambient conditions over time may induce sensor-response fluctuations (i.e., drift). Breaking this status quo in poor sensor performance requires understanding the origins of design principles of existing sensors and bringing new principles to sensor designs. Existing gas sensors are single-output (e.g., resistance, electrical current, light intensity, etc.) sensors, also known as zero-order sensors (Karl Booksh and Bruce R. Kowalski, Analytical Chemistry, DOI: 10.1021/ac00087a718). Any zero-order sensor is undesirably affected by variable chemical background and sensor drift that cannot be distinguished from the response to an analyte. To address these limitations, we are developing multivariable gas sensors with independent responses, which are first-order analytical instruments. Here, we demonstrate self-correction against drift in two types of first-order gas sensors that operate in different portions of the electromagnetic spectrum. Our radiofrequency sensors utilize dielectric excitation of semiconducting metal oxide materials on the shoulder of their dielectric relaxation peak and achieve self-correction of the baseline drift by operation at several frequencies. Our photonic sensors utilize nanostructured sensing materials inspired by Morpho butterflies and achieve self-correction of the baseline drift by operation at several wavelengths. These principles of self-correction for drift effects in first-order sensors open opportunities for diverse emerging monitoring applications that cannot afford frequent periodic maintenance that is typical of traditional analytical instruments.

© 2023 The Author(s)

PDF Article
More Like This
High-order harmonic generation from a dual-gas, multi-jet array with individual gas jet control

M. G. Pullen, N. S. Gaffney, C. R. Hall, J. A. Davis, A. Dubrouil, H. V. Le, R. Buividas, D. Day, H. M. Quiney, and L. V. Dao
Opt. Lett. 38(20) 4204-4207 (2013)

Heimdallr, Baldr, and Solarstein: designing the next generation of VLTI instruments in the Asgard suite

Adam K. Taras, J. Gordon Robertson, Fatme Allouche, Benjamin Courtney-Barrer, Josh Carter, Fred Crous, Nick Cvetojevic, Michael Ireland, Stephane Lagarde, Frantz Martinache, Grace McGinness, Mamadou N’Diaye, Sylvie Robbe-Dubois, and Peter Tuthill
Appl. Opt. 63(14) D41-D49 (2024)

Next-generation Raman tomography instrument for non-invasive in vivo bone imaging

Jennifer-Lynn H. Demers, Francis W.L. Esmonde-White, Karen A. Esmonde-White, Michael D. Morris, and Brian W. Pogue
Biomed. Opt. Express 6(3) 793-806 (2015)

Supplementary Material (1)

NameDescription
Supplement 1       sj-docx-1-asp-10.1177_00037028231186821 - Supplemental material for First-Order Individual Gas Sensors as Next Generation Reliable Analytical Instruments

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.