Mid-IR Spectroscopy for the Quantification of Metal Ions in Aqueous Solution in the Nanogram Range

Not Accessible

Your library or personal account may give you access

Abstract

A novel mid-infrared (IR) flow-through sensor system for the determination of metal ions in aqueous solution was developed. The flow-through sensor comprised weak cation exchanger beads (Sephadex with carboxylic acid moieties) placed in the optical path of a 37 μm IR transmission cell. The combination of the flow-through sensor with a sequential injection analysis (SIA) system allowed us to carry out the whole analysis procedure including analyte-sensor interaction and sensor regeneration, as well as data acquisition, under computer control. The first step of an analysis sequence was regeneration of the flow-through sensor by rinsing with diluted (0.012 M) hydrochloric acid followed by distilled water, thus protonating the carboxylic acid moieties. Then, after acquisition of a background spectrum and pumping 500 μL of sample followed by 1000 μL of distilled water through the flow-through sensor, the sample spectrum was recorded. Upon passage of the sample, the metal ions were retained on the cation exchanger, giving rise to spectral changes mainly resulting from the exchange of the protons by metal cations. It was found that the spectral changes were characteristic for the metal cations investigated. This observation was exploited to construct a multivariate calibration model for the simultaneous determination of calcium and magnesium ions in water. The developed method covered the range from 0 to 200 nmol for each cation (root mean square error of cross-validation: 9.2, and 7.6 nmol for Ca<sup>2+</sup> and Mg<sup>2+</sup>, respectively) and was successfully applied to the determination of the water hardness of the tap water in our laboratory.

PDF Article
More Like This
Matrix effect of sodium compounds on the determination of metal ions in aqueous solutions by underwater laser-induced breakdown spectroscopy

Christian Goueguel, Dustin L. McIntyre, Jinesh Jain, Athanasios K. Karamalidis, and Cantwell Carson
Appl. Opt. 54(19) 6071-6079 (2015)

Computer design of liquid filters made of aqueous solutions of transition metal ions

P. Laporta and F. Zaraga
Appl. Opt. 20(17) 2946-2950 (1981)

Mid-IR sensing platform for trace analysis in aqueous solutions based on a germanium-on-silicon waveguide chip with a mesoporous silica coating for analyte enrichment

Nuria Teigell Benéitez, Bettina Baumgartner, Jeroen Missinne, Sanja Radosavljevic, Dominik Wacht, Stefan Hugger, Paweł Leszcz, Bernard Lendl, and Gunther Roelkens
Opt. Express 28(18) 27013-27027 (2020)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.