Visual encoder-based angle measurement method in low-frequency angular vibration calibration

Not Accessible

Your library or personal account may give you access

Abstract

Angular vibration calibration is required to determine the sensitivity of sensors such as dynamic inclinometers, gyroscopes, and angular accelerometers, which are used for angular motion measurement in engineering applications. Additionally, the calibration performance depends on the accuracy of the angle measurement by laser interferometry or a circular grating (CG) method that is commonly used in vibration calibration. However, these methods usually own a complex and high-cost system or limited frequency and amplitude ranges. In this study, a novel, to the best of our knowledge, angle measurement method that combines a special visual encoder and an accurate angular position detection method is investigated; the method requires only a simple and flexible telecentric vision measurement system. Comparison experiments with the CG method demonstrate that the investigated method has the maximum measurement deviation of 0.0014° and 0.0138° for static angle measurement in the small-angle range and continuous full circle, respectively. The relative deviation of the angular vibration measurement in the range of 0.1–8 Hz with amplitudes 0–100° is less than 0.173%. Additionally, the relative deviation of calibrated sensitivity of a gyroscope by the investigated and CG methods is less than 0.096%.

© 2022 Optica Publishing Group

Full Article  |  PDF Article
More Like This
Efficient monocular vision method used for measuring the angular rate and acceleration in rotation motion

Ming Yang, Hanglei An, Sifan Mo, Huinan Gong, Bingbing Dong, and Guanggui Chen
Opt. Express 30(25) 45436-45446 (2022)

Monocular vision-based dynamic calibration method for determining the sensitivities of low-frequency tri-axial vibration sensors

Wenfeng Liu, Chenguang Cai, Zhihua Liu, Ming Yang, Shengnan Zuo, and Peicheng Wang
Opt. Express 32(6) 10130-10145 (2024)

Monocular vision-based low-frequency vibration calibration method with correction of the guideway bending in a long-stroke shaker

Ming Yang, Ying Wang, Chenguang Cai, Zhihua Liu, Haijiang Zhu, and Shengyang Zhou
Opt. Express 27(11) 15968-15981 (2019)

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (10)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (10)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.