Abstract
We investigate the temperature dependence of a refractive index (RI) sensor based on a macrobending micro-plastic optical fiber (m-POF) both theoretically and experimentally. The performance of the RI sensor at different temperatures (10°C–70°C) is measured and simulated over an RI range from 1.33 to 1.45. It is found that the temperature dependent bending loss and RI measurement deviation monotonically change with temperature, and the RI deviation has a higher gradient with temperature variation for a higher measured RI. Because of the linear trend of temperature dependence of the sensor, it is feasible to correct for changes in ambient temperature.
© 2015 Optical Society of America
Full Article | PDF ArticleMore Like This
Ning Jing, Jie Zheng, Xiaowei Zhao, and Chuanxin Teng
Appl. Opt. 53(34) 8145-8150 (2014)
Chuanxin Teng, Ning Jing, Fangda Yu, Yue Ding, and Jie Zheng
Appl. Opt. 56(7) 1833-1838 (2017)
Chuanxin Teng, Xinjing Li, Ming Chen, Shijie Deng, Hongchang Deng, Minmin Xue, Libo Yuan, Rui Min, Xiaosong Fu, and Xuehao Hu
Biomed. Opt. Express 15(2) 793-801 (2024)