Abstract
See-through-wall coherent microwave scattering from resonance-enhanced multiphoton ionization (REMPI) for rotational temperature measurements of molecular oxygen has been developed and demonstrated in a flow reactor at atmospheric pressure. Through limited, single-ended optical access, a laser beam was focused to generate local ionization of molecular oxygen in a heated quartz flow reactor enclosed by ceramic heating elements. Coherent microwaves were transmitted, and the subsequent scattering off the laser-induced plasma was received, through the optically opaque ceramic heater walls and used to acquire rotational spectra of molecular oxygen and to determine temperature. Both axial and radial air-temperature profiles were obtained in the flow reactor with an accuracy of . The experimental results show good agreement with a steady-state computational heat transfer model. This technique shows great potential for non-invasive, high-fidelity measurement of spatially localized temperature and radical species concentration in combustion kinetic experiments and confined combustors constructed of advanced ceramic materials in which limited or non-existing optical access hinders usage of conventional optical diagnostic techniques to quantify thermal non-uniformity.
© 2016 Optical Society of America
Full Article | PDF ArticleMore Like This
Yue Wu, Mark Gragston, and Zhili Zhang
Opt. Lett. 42(17) 3415-3418 (2017)
Yue Wu, Jordan Sawyer, Zhili Zhang, and Steven F. Adams
Appl. Opt. 51(28) 6864-6869 (2012)
Yue Wu, Zhili Zhang, and Timothy M. Ombrello
Opt. Lett. 38(13) 2286-2288 (2013)