Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Maskless fabrication of concave microlens arrays on silica glasses by a femtosecond-laser-enhanced local wet etching method

Open Access Open Access

Abstract

A simple and efficient technique for large-area manufacturing of concave microlens arrays (MLAs) on silica glasses with femtosecond (fs)-laser-enhanced chemical wet etching is demonstrated. By means of fs laser in situ irradiations followed by the hydrofluoric acid etching process, large area close-packed rectangular and hexagonal concave MLAs with diameters less than a hundred of micrometers are fabricated within a few hours. The fabricated MLAs exhibit excellent surface quality and uniformity. In contrast to the classic thermal reflow process, the presented technique is a maskless process and allows the flexible control of the size, shape and the packing pattern of the MLAs by adjusting the parameters such as the pulse energy, the number of shots and etching time.

©2010 Optical Society of America

1. Introduction

Microlenses arrays (MLAs) are important optical devices due to their diverse applications in optical systems, micro-manufacturing and biochemical systems [14]. Numerous researchers have poured into lots of enthusiasm to the manufacturing of MLAs. However, the majority of well-established techniques, such as thermal reflow [5,6], hot embossing [7], droplet method [8], gray-tone (GT) photolithograph and laser direct writing (LDW) [9,10], are not suitable for the fabrication of concave or negative MLAs, which have extensive applications such as diffusers, compound refractive lens for focusing X-rays and carriers of DNA chips [1113].

During the last decade, some techniques for the fabrication of concave MLAs have been proposed. For example, a concave refractive microlens array was fabricated in solgel glasses by a proximity-effect-assisted reflow technique, which was proposed in 2004 [14]. Later on, Ruffieux and associates developed a two-step process for fabrication of diffraction limited concave microlens arrays [11]. First, cylindrical holes were produced by the photolithograph method followed by a melting step preformed at 150°C for half an hour; the melted structures were then filled by a second spinning step of photoresist. Other techniques such as 3D diffuser lithograph and “breath figures” method [15,16], which were employed to fabricate concave molds, can also fabricate the concave MLAs. Moreover, through the reversal replication technique, the concave MLAs could be produced by the convex MLAs. We notice that most approaches to the fabrication of concave MLAs are based on the process using the photomasks, which are very expensive. The maskless processes such as LDW are complex and inefficient, which are not suitable for the large area fabrication of concave MLAs. Herein, a simple, high-efficient maskless technique for the concave MLAs is developed using a femtosecond (fs) laser-induced crater arrays followed by a chemical etching process. This method simplifies the classic laser etching process [17,18], improving the fabrication efficiency significantly. In addition, it allows direct manufacturing of various concave MLAs on glasses, which have better physical and chemical properties than the photoresist, polymethylmethacrylate (PMMA) or polydimethylsiloxane (PDMS), and more importantly, the reflection loss of lights caused by the interfaces between the polymer layers and substrates is not exist. Other advantages, such as simple process, facile processing environment and flexible control of the size, the packing pattern and the shape of the MLAs by adjusting some parameters, are also demonstrated.

As an example, a rectangular and a hexagonal microlens array are fabricated and the fabrication process is described in section 2. The morphology and three-dimensional profiles of the MLAs are evaluated by a field-emission scanning electron microscope (FE-SEM, JEOL JSM-7000F) and a laser confocal scanning microscope (LCSM, Olympus LEXT OLS4000) respectively. The optical properties of the MLAs, such as the focal length and imaging abilities, are also test. The results are presented in section 3. In section 4, the relationship between the profile of the microlenses and the processing parameters such as chemical etching time, τ, the pulse energy, E, and the number of shots, N, is discussed. Finally, the conclusion is given in section 5.

2. Fabrication process

The rectangular and hexagonal-packed concave MLAs are fabricated by a three-step process, as depicted in Fig. 1 . Initially, ablation-induced craters with diameters of a few micrometers are induced on polished silica glass chips (10 × 10 × 1 mm3, China Daheng Group Inc., GCL-1202) using a 30-fs and 800-nm laser pulses at a repetition of 1 kHz (the laser source is a Ti: sapphire pulsed laser oscillator-amplifier system). The femtosecond laser, owing to its advantages of negligible thermal and shockwave-induced damages [19], when focused by an objective lens (NA = 0.5), can easily induce craters on transparent materials such as silica glasses without melting-ejections and cracks which will impact on the morphology of the fabricated microlenses. The diameter of the focal spot is about 1.4 μm (1/e). The pulse energy can be varied by a variable neutral density filter and the number of shots is controlled by a shutter. More details of the setup used here can be found in Ref [20]. Subsequently, the samples with craters are treated in 5% hydrofluoric (HF) acid solution assisted by an ultrasonic bath at 23°C. During this process, the chemical etching velocity is accelerated in the laser-induced craters and the concave spherical surfaces begin to form; the MLAs are consequently fabricated in tens of minutes. Finally, the samples are cleaned by the ultrasonic bath in acetone, alcohol and deionized water for 15 minutes, respectively, and dried in ambient air.

 figure: Fig. 1

Fig. 1 Schematic of the fabrication process. First, the laser pulses are focused by an objective lens, inducing crater arrays on the sample surface. Then, the sample is treated by ultrasonic-assisted HF etching. Finally, the sample is cleaned by the ultrasonic bath in acetone, alcohol and deionized water, respectively. The inset presents the 3D profile of the rectangular microlens array.

Download Full Size | PDF

The employed processing parameters for the rectangular and hexagonal MLAs, including the pulse energy, E, the number of shots, N, the chemical etching time, τ, and the distance between adjacent microlenses, L, are listed in Table 1 . We note that the size, the packing pattern and the profile of the MLAs are close-related to these parameters, which will be discussed in Section 4.

Tables Icon

Table 1. Processing parameters used for the rectangular (Rec.) and hexagonal-packed (Hex.) MLAs

3. Results

In the experiment, the whole fabrication process is monitored by an optical microscope (OM) equipped with a CCD camera. Figure 2 shows the evolution of the rectangular and hexagonal MLAs changing from the laser-induced crater arrays. In the beginning, the isotropic chemical etching occurs in the laser treated points [black dots shown in Figs. 1(a) and 1(d)], producing circular-shaped concave structures in the rectangular [Fig. 1(b)] or hexagonal [Fig. 1(e)] patterns, which can serve as the circular MLAs. Then the aperture diameter of the circular microlenses expands gradually with the chemical etching, and eventually, the adjacent ones “overlapped” with each other, resulting in the formation of the tetragonal and hexagonal shaped microlenses, as shown in Figs. 1(c) and 1(f). It demonstrates that the packing pattern and the shape of the microlenses can be easily controlled by the arrangement of the laser irradiated points and the chemical etching time. The areas of the fabricated rectangular and hexagonal MLAs are about 3 × 3 mm2 and 1.5 × 1.5 mm2, respectively, and the whole processing time is about 3 hours, which is more efficient than the LDW process [20]. Figures 3(a) and 3(b) show the SEM images of the rectangular and hexagonal MLAs, respectively. They visually express the excellent surface quality and uniformity of the MLAs.

 figure: Fig. 2

Fig. 2 Morphology revolution of the samples at different stage of the fabrication process. For (a)-(c) the rectangular microlens array, the chemical etching time, t, is 0, 45 and 90 min, respectively. The hexagonal-packed microlens array are present in (d)-(f), and t = 0, 25 and 45 min, respectively. The images are captured by an optical microscope with tungsten light source.

Download Full Size | PDF

 figure: Fig. 3

Fig. 3 FE-SEM images of (a) the rectangular microlens array and (b) hexagonal microlens array.

Download Full Size | PDF

The three-dimensional (3D) morphology of the MLAs is observed by the LCSM. Figure 4 presents the 3D and the cross-section profile of the rectangular [Figs. 4(b) and 4(a)] and the hexagonal MLAs [Figs. 4(c) and 4(d)]. The measurement results show that the diameter, D, of the former one is 67.05 μm, and the sag depth, h, is 10.68 μm. For the latter one, D and h are 30.54 μm and 3.35 μm, respectively. By a primary equation: R = (h 2 + r 2)/2h (1), where r is the radius of the microlens (D/2), the values of the curvature radius, R, can be figured out and the results are 57.96 μm and 36.48 μm for the rectangular and hexagonal MLAs, respectively. In addition, the arithmetic-mean surface roughness value, Ra, is measured in an area of 258 × 258 μm2 for both rectangular and hexagonal MLAs and the results are 71 nm and 48 nm, respectively. The values of surface roughness obtained in this work are higher than those fabricated by the reflow techniques, but are much smaller than the microlenses fabricated by the femtosecond laser ablation, which was about 200 nm [20].

 figure: Fig. 4

Fig. 4 The results of 3D measurements of the MLAs. (a) and (b), the cross-section and the 3D profiles of the rectangular microlens array. The aperture diameter, D, and the sag height, h, of the microlens array are about 67.05 μm and 10.28 μm, respectively. (c) and (d), the 3D and cross-section profiles of the hexagonal-packed microlens array. D = 30.54 μm, h = 3.35 μm.

Download Full Size | PDF

To evaluate the focal length of the MLAs, fexp, an optical system equipped with a He-He laser (633 nm), a computer-controlled stage, a lens and a CCD camera, is built up, as shown in Fig. 5 . Moving the computer-controlled stage along the direction parallel to the laser beam (z-axis), the position of the top surface and the focal point can determined by the images captured by the CCD camera. The values of fexp are obtained by equation, fexp = L - h, where L is the distance between the focal point and the top surface of the MLAs. The focal length of the rectangular and the hexagonal MLAs is 125.0 ± 5 μm and 84.0 ± 5 μm, respectively. These values match well with the calculated focal length, fcal, which are obtained by equations: fcal = R/[n-1] (2), where n denotes for the refractive index of the silica glass at wavelength of 633 nm. Considering n = 1.45, the values of fcal are 128.80 μm and 81.06 μm for the rectangular and hexagonal MLAs. Furthermore, the values of numerical aperture, NA, for both MLAs are calculated by equation: NA = D/2f (3), and the results are 0.26 and 0.19, respectively. The experimental results are summarized in Table 2 .

 figure: Fig. 5

Fig. 5 Schematic of the optical system for the measurement of the focal length. The inset (bottom) is the CCD images of the sample surface (z = 0 μm) and the focal point (z = 84 μm).

Download Full Size | PDF

Tables Icon

Table 2. The measurement results of the MLAs

Figure 6 shows the imaging ability of the rectangular [Fig. 6(a)] and the hexagonal MLAs [Fig. 6(b)]. A mask with letters, “FE”, was fabricated by the focused femtosecond laser pulses on a glass-based 100-nm Au thin film. Then it was inserted between a tungsten light source and the MLAs. Consequently, reduced false images were captured by an objective lens (NA = 0.3) and the CCD camera which are placed on the other side of the MLAs, as shown in Fig. 6. The entire width of the images for rectangular and hexagonal microlens array is 8.9 μm and 11.7 μm, respectively.

 figure: Fig. 6

Fig. 6 The false images captured by the OM system for (a) rectangular microlens array and (b) hexagonal microlens array.

Download Full Size | PDF

4. Discussions

It has been mentioned that the profile of the microlens can be controlled by the processing parameters, such as τ, E and N. To investigate the profile revolution of the microlenses versus the chemical etching time, τ, groups of craters are induced on the silica glass at E = 1.1 μJ and N = 500, and they are treated by the 5% HF acid solution for different times. For each group, the aperture diameter, D, and the sag height, h, are the average values calculated by ten microlenses. The etching time dependency of D and h are plotted in Fig. 7(a) and 7(b), respectively. It is easy to see that D and h increase with the increase of τ and the increasing process consist of two different parts. For the further analysis, the two parts are fitted exponentially and linearly, and the curves are shown in Figs. 7(a) and 7(b). They can be expressed by Eqs. (4) and (5):

 figure: Fig. 7

Fig. 7 The evolutions of (a) the aperture diameter, D, and (b) the sag height, h, of the microlens versus the chemical etching time, τ.

Download Full Size | PDF

{D=22.76exp(τ11.69)+26.04 (μm)τ[0,20min)D=0.49τ+11.92 (μm)τ[20min,+),
{h=exp(1.37τ+0.62+1.82) (μm)τ[0,20min)h=0.002τ+6.17 (μm)τ[20min,+).

In addition, the variation ratio of the aperture diameter and sag height versus, VD and Vh, are given by the derivation of the D and h:

{VD=Dτ=1.95exp(τ11.69) (μm/min)τ[0,20min)VD=Dτ=0.49 (μm/min)τ[20min,+),
{Vh=Dτ=1.37(τ+0.62)2exp(1.37τ+0.62+1.82) (μm/min)τ[0,20min)Vh=Dτ=0.002 (μm/min)τ[20min,+),

From the figures and the equations, the etching processes for both D and h can be divided into the early stage (0-20 min) and the later stage (after 20 min) by the critical timeτ = 20 min. At the early stage, both D and h increases with the increase of etching time, but the variation ratio, VD and Vh, are decreasing. For example, when τ = 1 min, the values of VD and Vh is 1.79 μm/min and 1.38 μm/min, respectively, which are much higher than that after 20 min. At the later stage, D increases linearly with τ at a velocity of 0.49 μm/min. This value is close to the etching velocity of untreated silica glasses in 5% HF solutions at room temperature. However, the value of h stops increasing and kept to about 6 μm at this stage (Vh = 0.002 μm/min). This is because at the early stage, the etching velocity of the bottom of the microlenses is higher than that of the top surface, and h, which is the distance between the top and the bottom surfaces, keep increasing. When τ ≥ 20 min, both velocities are identical; and therefore h keeps a constant. It means that the value of h for a microlens is determined by its early stage of etching process, and the prolongation of the etching process will enlarge the curvature radius of the microlens because the aperture diameter keeps increasing and sag height keeps constant.

We believe that the enhancement of the etching velocity for both D and h at the early stage of the chemical wet etching process is associated with the fs-irradiation-induced modifications of materials [2123]. Figure 8(a) shows the morphology of an untreated crater irradiated by 500 pulses at E = 1.1 μJ. Nanostructures such as the parallel grooves and protrusions can be observed in the crater. These structures and defects will increase the interface of the samples surface and HF solutions, accelerating the etching process in the crater. The modified regions will be gradually etched by the chemical corrosion. The diameter and depth of the concave structure are increasing and the surface roughness decreases until τ = 20 min, when the modified materials are completely removed. At τ = 20 min, as shown in Fig. 8(d), the roughness of the bottom surface is close to the top surface and the chemical etching process come into the later stage. When τ = 50 min, a fine circular-shape concave microlens forms, as shown in Fig. 8(f). The eventual shape of the microlens seems to be independent with the original profile of the laser-induced craters. So to speak, rigorous demands for the morphology of the craters are unnecessary, which is facile to be obtained.

 figure: Fig. 8

Fig. 8 FE-SEM images of the laser-induced craters (a) before the HF treatment and treated for (b) 1 min, (c) 5 min, (d) 20 min, (e) 30 min and (f) 50 min. Note the different scale bars.

Download Full Size | PDF

Figure 9 presents the influence of the profiles of the microlenses on the pulse energy, E, and the number of shots, N. Here, D and h are also the average values obtained from ten microlenses treated by the 5% HF solutions for 120 min. We can see that D and h of the microlenses increase with the increase of E, as shown in Fig. 9(a) and 9(b) respectively, but they are not strongly dependent on N, which are present in Fig. 9(c) and 9(d). The curvature radiuses of these microlenses are figured out by the Eq. (1) and its dependency of E and N are spotted and fitted in Figs. 9(e) and 9(f). The maximum values of R tend to be obtained at the intermediate pulse energies (3.0-4.5 μJ), as demonstrated in Fig. 9(e). It is resulted from the different increase amplitude of D and h versus E. Take N = 1000 as an example, see Figs. 9(a) and 9(b), when E = 0.36 μJ, the aperture diameter of the fabricated microlens is about 45 μm, while E increases to 7.39 μJ, D increases to about 90 μm correspondingly, thus the increase amplitude of D is about 100%. However, this value is about 400% for h. According to the Eq. (1), the maximum R for N = 1000 is obtained when E is about 3.5 μJ. On the other hand, the values of D and h gradually reach saturation when the number of shots is more than 1000, as shown in Figs. 9(c) and 9(d), respectively. Consequently, the curvature radius of the microlenses has little relationship with N, as depict in Fig. 9(f). It is worth to mention that the increase of N is benefit for reducing the impact of the energy instability between the laser pulses and improving the uniformity of the MLAs, but it will also increase the processing time. The employed number of shots, N = 500, is an optimized value in our experiments.

 figure: Fig. 9

Fig. 9 Relationship between the processing parameters and the profile of microlenses. (a) and (b) show the energy dependency of aperture diameter, D, and sag height, h, respectively; (c) and (d) are the influence of the number of shots, N, on D, and h, respectively; (e) and (f) show the influence of E and N on the curvature radius of the microlens, respectively.

Download Full Size | PDF

5. Conclusion

To summarize, a femtosecond-laser-enhanced local chemical etching technique for efficient fabrication of concave MLAs on silica glasses has been demonstrated. Within 3 hours, a rectangular and a hexagonal microlens array with diameters of 67.05 μm and 30.54 μm were successfully manufactured in areas of 3 × 3 mm2 and 1.5 × 1.5 mm2, respectively. We believe that the femtosecond-laser-induced modification of the materials cause the enhancement of the chemical etching, resulting in the formation of concave structures. The profile of the microlens could be flexibly controlled by the chemical etching time. The diameter of the microlens, D, keeps increasing with the chemical etching process while the sag height, h, stops increasing at a critical time. Therefore, the curvature diameter of the microlens, R, increases with the chemical etching. In addition, D and h are also increase with the increase of the pulse energy. Correspondingly, the maximum value of R can be obtained at the intermediate energies.

Acknowledgments

This work is supported by the National Science Foundation of China under the Grant Nos. 60678011 and 10674107 and National High Technology R&D Program of China under the Grant No. 2009AA04Z305.

References and links

1. S. I. Chang, J. B. Yoon, H. Kim, J. J. Kim, B. K. Lee, and D. H. Shin, “Microlens array diffuser for a light-emitting diode backlight system,” Opt. Lett. 31(20), 3016–3018 (2006). [CrossRef]   [PubMed]  

2. F. Merenda, J. Rohner, J. M. Fournier, and R. P. Salathé, “Miniaturized high-NA focusing-mirror multiple optical tweezers,” Opt. Express 15(10), 6075–6086 (2007). [CrossRef]   [PubMed]  

3. M. H. Wu, C. Park, and G. M. Whitesides, “Fabrication of arrays of microlenses with controlled profiles using gray-scale microlens projection photolithography,” Langmuir 18(24), 9312–9318 (2002). [CrossRef]  

4. A. Deutsch, N. Zurgil, I. Hurevich, Y. Shafran, E. Afrimzon, P. Lebovich, and M. Deutsch, “Microplate cell-retaining methodology for high-content analysis of individual non-adherent unanchored cells in a population,” Biomed. Microdevices 8(4), 361–374 (2006). [CrossRef]   [PubMed]  

5. M. H. Wu and G. M. Whitesides, “Fabrication of two-dimensional arrays of microlenses and their applications in photolithography,” J. Micromech. Microeng. 12(6), 747–758 (2002). [CrossRef]  

6. C. P. Lin, H. Yang, and C. K. Chao, “Hexagonal microlens array modeling and fabrication using a thermal reflow process,” J. Micromech. Microeng. 13(5), 775–781 (2003). [CrossRef]  

7. N. S. Ong, Y. H. Koh, and Y. Q. Fu, “Microlens array produced using hot embossing process,” Microelectron. Eng. 60(3–4), 365–379 (2002). [CrossRef]  

8. D. L. MacFarlane, V. Narayan, J. A. Tatum, W. R. Cox, T. Chen, and D. J. Hayes, “Microjet fabrication of microlens arrays,” IEEE Photon. Technol. Lett. 6(9), 1112–1114 (1994). [CrossRef]  

9. J. Yao, J. Q. Su, J. L. Du, Y. X. Zhang, F. H. Gao, F. Gao, Y. K. Guo, and Z. Cui, “Coding gray-tone mask for refractive microlens fabrication,” Microelectron. Eng. 53(1-4), 531–534 (2000). [CrossRef]  

10. T. Chen, T. Wang, Z. Wang, T. Zuo, J. Wu, and S. Liu, “Microlens fabrication using an excimer laser and the diaphragm method,” Opt. Express 17(12), 9733–9747 (2009). [CrossRef]   [PubMed]  

11. P. Ruffieux, T. Scharf, I. Philipoussis, H. P. Herzig, R. Voelkel, and K. J. Weible, “Two step process for the fabrication of diffraction limited concave microlens arrays,” Opt. Express 16(24), 19541–19549 (2008). [CrossRef]   [PubMed]  

12. A. Snigirev, V. Kohn, I. Snigireva, and B. Lengeler, “A compound refractive lens for focusing high-energy X-rays,” Nature 384(6604), 49–51 (1996). [CrossRef]  

13. M. Schena, D. Shalon, R. W. Davis, and P. O. Brown, “Quantitative monitoring of gene expression patterns with a complementary DNA microarray,” Science 270(5235), 467–470 (1995). [CrossRef]   [PubMed]  

14. M. He, X. Yuan, J. Bu, and W. C. Cheong, “Fabrication of concave refractive microlens arrays in solgel glass by a simple proximity-effect-assisted reflow technique,” Opt. Lett. 29(9), 1007–1009 (2004). [CrossRef]   [PubMed]  

15. S. I. Chang, J. B. Yoon, H. Kim, J. J. Kim, B. K. Lee, and D. H. Shin, “Microlens array diffuser for a light-emitting diode backlight system,” Opt. Lett. 31(20), 3016–3018 (2006). [CrossRef]   [PubMed]  

16. C. Y. Wu, T. H. Chiang, and C. C. Hsu, “Fabrication of microlens array diffuser films with controllable haze distribution by combination of breath figures and replica molding methods,” Opt. Express 16(24), 19978–19986 (2008). [CrossRef]   [PubMed]  

17. areC. H. Lin, L. Jiang, Y. H. Chai, H. Xiao, S. J. Chen, and H. L. Tsai, “Fabrication of microlens arrays in photosensitive glass by femtosecond laser direct writing,” Appl. Phys., A Mater. Sci. Process. 97(4), 751–757 (2009). [CrossRef]  

18. R. Guo, S. Xiao, X. Zhai, J. Li, A. Xia, and W. Huang, “Micro lens fabrication by means of femtosecond two photon photopolymerization,” Opt. Express 14(2), 810–816 (2006). [CrossRef]   [PubMed]  

19. K. Furusawa, K. Takahashi, S. H. Cho, H. Kumagai, K. Midorikawa, and M. Obara, “Femtosecond laser micromachining of TiO2 crystal surface for robust optical catalyst,” J. Appl. Phys. 87(4), 1604–1609 (2000). [CrossRef]  

20. H. Liu, F. Chen, X. Wang, Q. Yang, D. Zhang, J. Si, and X. Hou, “Photoetching of spherical microlenses on glasses using a femtosecond laser,” Opt. Commun. 282(20), 4119–4123 (2009). [CrossRef]  

21. J. Bonse, S. Baudach, J. Kruger, W. Kautek, and M. Lenzner, “Femtosecond laser ablation of silicon-modification thresholds and morphology,” Appl. Phys., A Mater. Sci. Process. 74(1), 19–25 (2002). [CrossRef]  

22. D. J. Little, M. Ams, P. Dekker, G. D. Marshall, J. M. Dawes, and M. J. Withford, “Femtosecond laser modification of fused silica: the effect of writing polarization on Si-O ring structure,” Opt. Express 16(24), 20029–20037 (2008). [CrossRef]   [PubMed]  

23. S. Matsuo, Y. Tabuchi, T. Okada, S. Juodkazis, and H. Misawa, “Femtosecond laser assisted etching of quartz: microstructuring from inside,” Appl. Phys., A Mater. Sci. Process. 84(1-2), 99–102 (2006). [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (9)

Fig. 1
Fig. 1 Schematic of the fabrication process. First, the laser pulses are focused by an objective lens, inducing crater arrays on the sample surface. Then, the sample is treated by ultrasonic-assisted HF etching. Finally, the sample is cleaned by the ultrasonic bath in acetone, alcohol and deionized water, respectively. The inset presents the 3D profile of the rectangular microlens array.
Fig. 2
Fig. 2 Morphology revolution of the samples at different stage of the fabrication process. For (a)-(c) the rectangular microlens array, the chemical etching time, t, is 0, 45 and 90 min, respectively. The hexagonal-packed microlens array are present in (d)-(f), and t = 0, 25 and 45 min, respectively. The images are captured by an optical microscope with tungsten light source.
Fig. 3
Fig. 3 FE-SEM images of (a) the rectangular microlens array and (b) hexagonal microlens array.
Fig. 4
Fig. 4 The results of 3D measurements of the MLAs. (a) and (b), the cross-section and the 3D profiles of the rectangular microlens array. The aperture diameter, D, and the sag height, h, of the microlens array are about 67.05 μm and 10.28 μm, respectively. (c) and (d), the 3D and cross-section profiles of the hexagonal-packed microlens array. D = 30.54 μm, h = 3.35 μm.
Fig. 5
Fig. 5 Schematic of the optical system for the measurement of the focal length. The inset (bottom) is the CCD images of the sample surface (z = 0 μm) and the focal point (z = 84 μm).
Fig. 6
Fig. 6 The false images captured by the OM system for (a) rectangular microlens array and (b) hexagonal microlens array.
Fig. 7
Fig. 7 The evolutions of (a) the aperture diameter, D, and (b) the sag height, h, of the microlens versus the chemical etching time, τ.
Fig. 8
Fig. 8 FE-SEM images of the laser-induced craters (a) before the HF treatment and treated for (b) 1 min, (c) 5 min, (d) 20 min, (e) 30 min and (f) 50 min. Note the different scale bars.
Fig. 9
Fig. 9 Relationship between the processing parameters and the profile of microlenses. (a) and (b) show the energy dependency of aperture diameter, D, and sag height, h, respectively; (c) and (d) are the influence of the number of shots, N, on D, and h, respectively; (e) and (f) show the influence of E and N on the curvature radius of the microlens, respectively.

Tables (2)

Tables Icon

Table 1 Processing parameters used for the rectangular (Rec.) and hexagonal-packed (Hex.) MLAs

Tables Icon

Table 2 The measurement results of the MLAs

Equations (4)

Equations on this page are rendered with MathJax. Learn more.

{ D = 22.76 exp ( τ 11.69 ) + 26.04   ( μm ) τ [ 0 , 20 min ) D = 0.49 τ + 11.92   ( μm ) τ [ 20 min , + ) ,
{ h = exp ( 1.37 τ + 0.62 + 1.82 )   ( μm ) τ [ 0 , 20 min ) h = 0.002 τ + 6.17   ( μm ) τ [ 20 min , + ) .
{ V D = D τ = 1.95 exp ( τ 11.69 )   ( μm/min ) τ [ 0 , 20 min ) V D = D τ = 0.49   ( μm/min ) τ [ 20 min , + ) ,
{ V h = D τ = 1.37 ( τ + 0.62 ) 2 exp ( 1.37 τ + 0.62 + 1.82 )   ( μm/min ) τ [ 0 , 20 min ) V h = D τ = 0.002   ( μm/min ) τ [ 20 min , + ) ,
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.