Abstract
The technique of dc-balanced, pulsed homodyne detection for the purpose of determining optical-field statistics on short time scales is analyzed theoretically. Such measurements provide photon-number and phase distributions associated with a repetitive signal light field in a short time window. Time- and space-varying signal and local-oscillator pulses are treated, thus generalizing earlier treatments of photoelectron difference statistics in homodyne detection. Experimental issues, such as the effects of imperfect detector balancing on (time-integrated) dc detection and the consequences of background noise caused by non-mode-matched parts of the multimode signal field, are analyzed. The Wigner, or joint, distribution for the two field-quadrature amplitudes during the sampling time window can be directly determined by tomographic inversion of the measured photoelectron distributions. It is pointed out that homodyne detection provides a new method for the simultaneous measurement of temporal and spectral information. Although the theory is generally formulated, with both signal and local-oscillator fields being quantized, emphasis is placed on the limit of a strong, coherent local-oscillator field, making semiclassical interpretation possible.
© 1995 Optical Society of America
Full Article | PDF ArticleMore Like This
A. Auyuanet, E. Benech, H. Failache, and A. Lezama
J. Opt. Soc. Am. B 36(1) 140-145 (2019)
H. Hansen, T. Aichele, C. Hettich, P. Lodahl, A. I. Lvovsky, J. Mlynek, and S. Schiller
Opt. Lett. 26(21) 1714-1716 (2001)
Bing Qi, Pavel Lougovski, and Brian P. Williams
Opt. Express 28(2) 2276-2290 (2020)