Abstract
An evaporation rate measurement method based on multiple reflection interference using a simple fiber optic configuration is proposed in this study. The evaporation rate is a major factor in preventing accidents and is used in various industrial, chemical, biotechnological, and biological fields. The evaporation rate sensor measures the interference signal during evaporation of a liquid. The main frequency of an interferogram is linearly proportional to the evaporation rate and can be obtained by applying a fast Fourier transform to the interferogram. In our study, the time-averaged evaporation rates of deionized (DI) water and ethanol were tested. Ethanol evaporated at a rate approximately a factor four faster than that of DI water. In addition, a Hilbert transform was used to retrieve the phase information of the interferogram over time. Our proposed method is a powerful tool for monitoring the evaporation dynamics of a liquid in time. The sensor requires a tiny amount of liquid as a test sample to determine the rate of evaporation and offers high reliability and reproducibility at low cost.
© 2019 IEEE
PDF Article
More Like This
Cited By
You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator