Abstract
Digital in-line holography (DIH) with a divergent beam is used to measure size and concentration of cavitation bubbles () in hydrodynamic facilities. A sampling probe is directly inserted in the cavitation tunnel, and the holograms of the bubbles are recorded through a transparent test section specially designed for DIH measurements. The recording beam coming from a fiber-coupled laser diode illuminates the sample volume, and holograms are recorded by a CMOS camera. From each hologram, the sampling volume can be reconstructed slice by slice by applying a wavelet-based reconstruction method. Because of the geometry of the recording beam, a magnification ratio must be introduced for recovering the 3D location and size of each bubble. The method used for processing holograms recorded in such a configuration is presented. Then, statistical results obtained from 5000 holograms recorded under different pressures in the cavitation tunnel are compared and discussed.
© 2011 Optical Society of America