Alain Barbe,
Marie-Renée De Backer-Barilly,
Vladimir G. Tyuterev,
and Serguei A. Tashkun
A. Barbe (alain.barbe@univ-reims.fr), M.-R. De Backer-Barilly, and V. G. Tyuterev are with Groupe de Spectrométrie Moléculaire et Atmosphérique, Unité Mixte de Recherche, Centre National de la Recherche Scientifique 6089, UFR Sciences, BP 1039, 51687 Reims Cedex France.
S. A. Tashkun is with the Laboratory of Theoretical Spectroscopy, Institute of Atmosphere Optics, 1 Akademicheskii Avenue, 634055, Tomsk, Russia.
Alain Barbe, Marie-Renée De Backer-Barilly, Vladimir G. Tyuterev, and Serguei A. Tashkun, "Observations of infrared bands of asymmetrical ozone isotopologues 16O16O18O and 16O18O18O," Appl. Opt. 42, 5136-5139 (2003)
Infrared spectra (0.003 cm-1 resolution) of 16O16O18O and 16O18O18O ozone isotopologues have been recorded and analyzed in the range 600–5000 cm-1. Several thousand rovibrational lines belonging to 32 absorption bands have been measured and assigned. An accurate determination of band centers through the rovibrational analysis has been done, 12 bands being observed for the first time to our knowledge. In addition to atmospheric retrieval applications, these results are also useful for a validation of potential energy surfaces and for the study of isotope effects in dynamic processes of ozone.
You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
This study (improved values with respect to the Ref. 13).
This study (new data).
This study (improved values with respect to the Ref. 25).
Obs., observed values; Calc., predicted values from Ref. 10.
This study (new data).
This study (improved values with respect to the reference 25).
This study (improved values with respect to the reference 24).
Obs., observed values; Calc., predicted values from Ref. 10.
Note: Notations are the same as in Table
2. The experimental uncertainty for band centers reported in Tables
2 and 3 vary alike absolute calibration and stays equal or better than 1 × 10-3 cm-1. The improvement of theoretical predictions10 compared with previous values3 is due to the use of exact kinetic energy Hamiltonian.
This study (improved values with respect to the Ref. 13).
This study (new data).
This study (improved values with respect to the Ref. 25).
Obs., observed values; Calc., predicted values from Ref. 10.
This study (new data).
This study (improved values with respect to the reference 25).
This study (improved values with respect to the reference 24).
Obs., observed values; Calc., predicted values from Ref. 10.
Note: Notations are the same as in Table
2. The experimental uncertainty for band centers reported in Tables
2 and 3 vary alike absolute calibration and stays equal or better than 1 × 10-3 cm-1. The improvement of theoretical predictions10 compared with previous values3 is due to the use of exact kinetic energy Hamiltonian.