Abstract
A design study was undertaken on an infrared, 3–5-μm, panoramic optical system for a particular monitoring application. The different types of systems investigated covered the conventional fish-eye lens system, a panoramic block arrangement, and a new type of configuration based on a panoramic shell. Examples of these systems are included, and their advantages and disadvantages are discussed.
© 1996 Optical Society of America
Full Article | PDF ArticleMore Like This
Ian Powell
Appl. Opt. 33(31) 7356-7361 (1994)
K. Siva Rama Krishna and Anurag Sharma
Appl. Opt. 35(28) 5636-5641 (1996)
Yun-han Huang, Zhi-ying Liu, Yue-gang Fu, and He Zhang
Opt. Express 25(22) 27691-27705 (2017)