Abstract
We demonstrate all-multicore-fiber parallel Fabry-Perot interferometers (FPIs) with individually variable cavity length of 26-61μm by femtosecond laser selective micro-machining and fiber fusion splicing, leading to the successful mitigation of cross-sensitivity arising in dual-parameter sensing.
© 2020 The Author(s)