Abstract
This paper reports instantaneous and volumetric flame measurements based on tomographic techniques. Experimental results at kHz temporal rate, in a volume of 16×16×16 cm3, and with a spatial resolution of 2~3 mm, are discussed.
© 2014 Optical Society of America