Partially coherent illumination engineering for enhanced refractive index tomography

Not Accessible

Your library or personal account may give you access

Abstract

Optical diffraction tomography based on partially coherent illumination (PC-ODT) is a quantitative label-free imaging technique that allows reconstructing of the object’s 3D refractive index from measured through-focus intensity images. PC illumination provides advantages such as speckle noise-free imaging and inherent compatibility with conventional wide-field microscopes. Here we experimentally demonstrate that a proper design of the PC illumination, different from the familiar bright-field one, and the use of more realistic optical transfer functions (OTFs) have crucial importance in PC-ODT to significantly increase the accuracy in 3D refractive index reconstruction. While realistic OTFs properly account for the real experimental illumination conditions, the proposed PC illumination design allows for gathering the object spatial-frequency content attenuated when bright-field illumination is used.

© 2018 Optical Society of America

Full Article  |  PDF Article
More Like This
Label-free quantitative 3D tomographic imaging for partially coherent light microscopy

Juan M. Soto, José A. Rodrigo, and Tatiana Alieva
Opt. Express 25(14) 15699-15712 (2017)

Three-dimensional tomographic microscopy technique with multi-frequency combination with partially coherent illuminations

Jiaji Li, Qian Chen, Jiasong Sun, Jialin Zhang, Junyi Ding, and Chao Zuo
Biomed. Opt. Express 9(6) 2526-2542 (2018)

Supplementary Material (2)

NameDescription
Visualization 1       Comparison of Phase Optical Transfer Functions for PC-ODT corresponding to different illuminations: BFI and GI, both for theoretical and experimental conditions. See Fig. 2.
Visualization 2       3D tomographic reconstruction of a diatom: Volumetric visualization of its refractive index distribution. It has been reconstructed by using partially coherent illumination and PC-ODT. See also Fig. 3.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (3)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved