Abstract
Industrial lasers are an expanding technology of welding and other materials processing. Lasers with optical scanning heads are often used, as these provide more versatility, accuracy, and speed. The output part of the scanning head is covered by a protective glass, which might get contaminated by various particles from the laser processing. This decreases the transmissivity of the glass, and it can affect the production quality. The contamination needs to be checked regularly, but a visual inspection might not always be effective. This paper proposes two alternative methods of inspecting the protective glass: flash-pulse active thermography, and laser active thermography. They are based on the thermal excitation of the glass and measuring the response with an infrared camera. The experimental setup and practical results are described and the advantages and disadvantages are discussed. The presented methods are proven to be effective in detecting the contamination of the glass.
© 2016 Optical Society of America
Full Article | PDF ArticleMore Like This
Henrique Fernandes, Hai Zhang, Alisson Figueiredo, Clemente Ibarra-Castanedo, Gilmar Guimarares, and Xavier Maldague
Appl. Opt. 55(34) D46-D53 (2016)
Zhenggan Zhou, Hanxue Zhao, Guangkai Sun, Pengfei He, Jin Fan, and Gen Li
Appl. Opt. 55(16) 4490-4496 (2016)
Boris G. Vainer
Appl. Opt. 55(34) D95-D100 (2016)