Abstract
The unique properties of the DORIS storage ring at DESY as a synchrotron radiation source are exploited for high resolution spectroscopy in the vacuum ultraviolet. We describe a new experimental set up with a 3-m normal incidence monochromator for wavelengths between 3000 Å and 300 Å (4 ≤ ħω ≤ 40 eV) using a vertical dispersion plane. The storage ring provides a light flux intense and stable enough for rapid photoelectrical scanning of the spectra with a resolution of 0.03 Å in first order.
© 1976 Optical Society of America
Full Article | PDF ArticleMore Like This
Marshall L. Ginter, Dorothy S. Ginter, and Charles M. Brown
Appl. Opt. 27(22) 4712-4724 (1988)
W. D. Duncan and Gwyn P. Williams
Appl. Opt. 22(18) 2914-2923 (1983)
J. Fischer, M. Kühne, and B. Wende
Appl. Opt. 23(23) 4252-4260 (1984)