Abstract
This Letter reports the integration of microlenses (MLs) on a surface-micromachined optical ultrasound transducer (SMOUT) array to enable parallel ultrasound data readout from a multiplicity of elements. The MLs are fabricated by photoresist patterning and reflow, and their focal lengths are optimized with parametric studies. Experiments are conducted to characterize the acoustic responsivity and its uniformity of the SMOUT-ML elements under different conditions. The temporal stability of SMOUT-ML elements immersed in water is assessed by monitoring their acoustic response continuously for 1 week. Parallel ultrasound signal readout is simulated with a small group of SMOUT-ML elements. Experimental results show that high acoustic sensitivity and excellent long-term stability can be achieved by the ML-integrated SMOUT array, which could provide a promising approach for enabling parallel ultrasound data acquisition for improving the imaging speed of 3D acoustic tomography.
© 2023 Optica Publishing Group
Full Article | PDF ArticleMore Like This
Zhiyu Yan and Jun Zou
Opt. Lett. 49(5) 1181-1184 (2024)
Zhiyu Yan and Jun Zou
Opt. Express 30(11) 19069-19080 (2022)
Afshin Kashani Ilkhechi, Christopher Ceroici, Eric Dew, and Roger Zemp
Opt. Lett. 46(7) 1542-1545 (2021)