Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

High-accuracy wide-range refractive index demodulation based on under-sampled fiber F-P cavity length spectrum

Not Accessible

Your library or personal account may give you access

Abstract

A scheme of fiber Fabry–Perot (F-P) cavity refractive index (RI) demodulation named under-sampled length spectrum retrieval (ULSR) is proposed. Unlike the wavelength spectrum method, ULSR can be used for physical quantity detection with just a monochromatic laser and photodetectors, avoiding the need for wideband lasers or expensive infrared spectrometers. Eight F-P cavities of different lengths were fabricated to sample the cavity length spectrum, and then the obtained under-sampled length spectrum was used to demodulate the RI of F-P cavity fillings. It was demonstrated that the ULSR system can achieve an index measurement accuracy of 1 × 10−4 in the glucose solution index range of 1.3294–1.3746 at wavelength λ = 1.55 µm. An index demodulation with higher accuracy and wider range is expected when more than 8 F-P cavities are used. The proposed scheme, with advantages of low system complexity, low cost, high reliability, high detecting accuracy, and wide detecting range, holds great promise for facilitating the wide application of F-P cavity sensors. Additionally, ULSR liberates wavelength freedom, making it a strong candidate for multiplexed sensing based on wavelength division multiplexing.

© 2023 Optica Publishing Group

Full Article  |  PDF Article
More Like This
TWDM-assisted passive quadrature phase demodulation for a Fabry–Perot-based ultrasound localization detection

Ying Zhao, Qiang Liu, Yang Cheung, Zhenguo Jing, and Wei Peng
Opt. Lett. 48(19) 5165-5168 (2023)

Fiber liquid-pressure sensor with high sensitivity and a wide measurement range using photopolymer

Yu Zhang, Wenjie Su, Yifan Qin, Jinhua Mou, Shixiong Li, Wei Jin, Yaxun Zhang, Zhihai Liu, and Libo Yuan
Opt. Lett. 48(14) 3641-3644 (2023)

Simultaneous measurement of refractive index and temperature based on a side-polish and V-groove plastic optical fiber SPR sensor

Teng Chuanxin, Peng Shao, Rui Min, Hongchang Deng, Ming Chen, Shijie Deng, Xuehao Hu, Carlos Marques, and Libo Yuan
Opt. Lett. 48(2) 235-238 (2023)

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (4)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (7)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.