Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Realization of a flat-response photocathode for x-ray streak cameras

Open Access Open Access

Abstract

We present a novel photocathode which can make x-ray streak cameras to be of a flat spectral response in the x-ray energy range of 0.1-5 keV. The photocathode consists of two layers of gold foils with optimized thickness ratio and structures. The photocathode was calibrated, and it is shown that a flat spectral response has been achieved.

© 2015 Optical Society of America

1. Introduction

X-ray streak cameras (XSC) [1–3] are extensively used for ultrafast x-ray diagnostics in the research field of inertial confined fusion (ICF) [4–6] as well as in high energy-density physics [7, 8] and fundamental research [9–11]. The ICF research performed on high-power laser facilities, such as NIF, OMEGA and Shenguang, requires x-ray flux measurements with high temporal resolution [12–15]. XSCs are used to obtain time-resolved images of fusion targets via a combination with x-ray imaging, and they are also used to obtain time-resolved spectra via a combination with x-ray crystal or grating spectrometers [16, 17].

Quantitative measurements of x-ray emissions are of importance for understanding laser absorption and energy transport in laser-fusion targets [17, 18]. However, conventional XSCs do not have flat spectral response, thus causing extra complexities to deduce the quantitative information. Usually, the photocathodes of XSCs are made of thin conductor or insulator materials which are of energy-dependent photoelectric conversion [19, 20]. As a consequence, the conventional XSCs have a complicated spectral response in the interested x-ray energy range [20–23]. To obtain the quantitative x-ray spectra, the images measured by XSCs must be corrected using a complex spectral response function of the photocathodes, and this procedure causes sophisticated uncertainties. Therefore, a flat-response, i.e., energy-independent, photocathode for XSCs is highly required for the quantitative measurements of ultrafast x-ray imaging or spectroscopy.

In this paper we present a flat-response photocathode for XSCs in the x-ray energy range of 0.1-5 keV. This type of photocathode does not need complex corrections in the interested x-ray energy range due to the flat-response characteristics. The accuracy of spectral data is thus improved. It is a technique to promote the quantitative studies of laser-produced plasmas in ICF research.

2. Design of the flat-response photocathode

The design is based on a reasonable assumption that the photoelectric coefficient is proportional to the absorption coefficient for the photocathode material [20, 21]. According to the formula for the yield of secondary electrons from a gold photocathode, the response of thin and thick gold foils complement each other. So the desired flat response in the range of 0.1-5 keV can be achieved with the help of the compound photocathode.

The energy-response function of the compound photocathode can be written as

S(E)ρu(E)λs[(1a)et1/λx(1et1/λs)+ae(t1+t2)/λx(1e(t1+t2)/λs)]

where ρ is the mass density of gold foils, u(E) the mass photoionization cross section, E the mean energy of the incident photons, t1 and t2 the thicknesses of the thinner and the thicker gold foils, λx the x-ray attenuation length, λs the effective escape depth of electrons, a the ratio of irradiated areas of the thicker gold foil to the thinner one. The parameters ρ, λs are constants for a specified metal material, whereas λx is the reciprocal of the product of ρ and u(E).

The flatness of the photon-energy response of the photocathode, which is defined as the ratio of the standard deviation σ of the response in the energy range, E1 to E2, can be expressed as

σ=E1E2(SS¯)2dx(E2E1)S¯2

where S¯ was obtained by the formula of S¯=E1E2S(x)dxE2E1. Based on Eqs. (1) and (2), the flat-response of the photocathode for x-ray streak cameras can be achieved by optimizing the thicknesses and the ratio of irradiated areas of the two gold foils.

By simulations, the photon-energy response is flat if t1 = 50 nm, t2 = 400 nm and a = 6/7, as shown in Fig. 1(a). However, there is a disadvantage of this design. In experiments, the spot of the x-ray beam on the photocathode must be carefully adjusted with suitable apertures to ensure that the ratio of irradiated areas of the two foils is the same as designed, however, it is not easily realized.

 figure: Fig. 1

Fig. 1 Schematic diagram of (a) the designed at-response photocathode, (b) the structure-improved photocathode, (c) the side-view profile of the cross section of the structure-improved photocathode and (d) the front view of the thicker gold foil which has uniformly distributed pin-holes.

Download Full Size | PDF

In order to overcome this difficulty, we propose a new type of compound photocathode to achieve the flat response. As shown in Fig. 1(b) and 1(c), the structure-improved photocathode is composed by two gold foils with the same diameters, whereas the thicker one has uniformly distributed pinholes with a designed duty cycle. As shown in Fig. 1, the thicker gold foil with pin-holes, which can also emit photoelectrons, is used to adjust the duty cycle. The thicknesses of the two gold foils and the duty cycle of the pin-holes were carefully optimized to obtain a flat x-ray absorption coefficient in the interested x-ray energy range. With this type of compound photocathode, the restricted requirements on the shape and the size of x-ray spot can be largely eliminated. In fact, the requirement in experiments is only that the size of the x-ray beam spot must cover a few hundred pin-holes; this can be easily realized in practical experiments.

3. Fabrication and calibration of the flat-response photocathode

To fabricate the photocathode, a hybrid lithography including electron-beam lithography and x-ray lithography was used [22–27]. The thinner one is 50 nm (t1) gold foil, the thicker one is 400 nm (t2) and has an array of 5 μm- diameter pin-holes. There are 8 × 103pinholes distributed on the thicker foil per square millimeter. Therefore, effectively, about 6/7 (a) of the photocathode area is filtered with the 450 nm gold foil and the rest is filtered with the 50 nm gold foil. The optimized parameters satisfy the required at response in the x-ray energy range of 0.1-5 keV, as shown in Fig. 3. Usually, the spatial resolution of X-ray streak cameras is not better than 15 μm, the flat response photocathode with 5 μm pinholes does not affect the spatial resolution. If the spatial resolution of the camera is required to be better than 15um, it can be achieved by reducing the pinhole diameter to 2 μm. So the spatial resolution of X-ray streak cameras with flat response photocathode will not be affected.

Two photocathodes with a diameter of 12mm were fabricated, and then calibrated on the Beijing Synchrotron Radiation Facility [28, 29] at the Institute of High Energy Physics, Chinese Academy of Science. The calibration-experiment arrangement is shown schematically in Fig. 2. The calibration procedure is almost the same as that by Campbell et al. [19]. A combination, which consists of a cylindrical mirror and a flat grating, was used as a monochromator to obtain quasi-mono-energetic x-rays with energies between 1.2 and 6 keV (beam-line 4B7A) and 0.1-1.6 keV (beam-line 4B7B), the energy spread is about 10 eV.

 figure: Fig. 2

Fig. 2 Schematic diagram of the calibration-experiment setup at the x-ray beam-lines at the Beijing Synchrotron Radiation Facility.

Download Full Size | PDF

The monochromatic x-ray beam normally irradiated on the photocathodes which are placed at the center of a vacuum chamber. An aperture was placed in front of the photocathodes to ensure the x rays irradiate the active surfaces exactly. When the photocathode sample was irradiated by the x-ray beam, secondary electrons were collected by a Cu foil, and the current I1(E) was measured by an ammeter 6517B. A standard Si-photodiode detector (AXUV-100) was placed behind the photocathode sample. The current I0(E) was measured by the same ammeter with a different channel when the photocathode was moved out of the x-ray beam. The detecting sensitivity Rsta of the standard photodiode detector was taken from NIST database, then the sensitivity R(E), namely, the energy-response, of the photocathode was deduced by

R(E)=I1(E)Rsta(E)I0(E).

The calibration results of two photocathode are shown in Fig. 3, and it shows that the energy response of photocathode 2 is nearly flat in the photon-energy range of 0.1-5 keV. The corresponding response flatness is 5.3% in the range of 0.1-1.6 keV and 8.3% in the range of 2.1-5 keV. The uncertainty due to the calibration is smaller than 3%, which stems from the standard Si-photodiode detector. The response flatness of photocathode 1 is not good, especially at the lower photon-energies. The marked deviation in 280-300eV range for photocathode 1 was caused by the absorption edge of carbon, it is mainly contributed by the polyamide supporting membrane which was used as an x-ray lithography mask in the fabrication procedure [22–25]. Polyamide has some advantages, such as tolerance for high temperatures and good stress characteristic, which allow for much more freedom in choosing the condition parameters of the subsequent processing procedure. Furthermore, polyamide membrane has higher transmission efficiency than silicon nitride in the x-ray region, which leads to less heat accumulation on the mask during x-ray lithography. In order to minimize the carbon contamination from the polyamide membrane, etching with low-temperature plasmas was used for photocathode 2. In Fig. 3, it is clearly shown that photocathode 2 has much smaller deviation from the calculation than photocathode 2 in the low-energy region.

 figure: Fig. 3

Fig. 3 Calculated and calibrated spectral responses of the photocathodes in the photon-energy range of 0.1-5 keV.

Download Full Size | PDF

3. Conclusion

In summary, the time-resolved x-ray measurement using XSCs is an important diagnosing means in ICF experiments. We presented a novel photocathode which can make it possible for XSCs to have a flat spectral response in the x-ray energy range of 0.1-5 keV. The calibration experiments show that the fabricated photocathodes have flat-response with flatnesses better than 9% in the x-ray energy range of 0.1-5 keV. With the help of the novel photocathode which was designed for XSCs, the ultrafast x-ray diagnostics can be advanced, thus promoting ICF research. For instance, to achieve a high-gain in ICF research, shaped pulses are being used [30]. X-ray flux due to the shaped pulse has fast changes with time, consequently, temporal resolution of the flux measurement is required up to sub-100-picoseconds. A flat-response x-ray diode detector was realized to diagnose time-resolved x-ray flux, however, the typical temporal resolution is worse than 100 picoseconds [31]. Therefore, the ultrafast x-ray diagnostics in ICF research would benefit from the flat-response XSCs because the temporal resolution of XSCs could achieve 10 picoseconds.

Acknowledgments

This work is supported by the Natural Science Foundation of China (Grant No. 11405158, 11435011) and the Development Foundation of China Academy of Engineering Physics (No. 2013B0102011). The authors gratefully thank Professor Mingqi Cui, Yidong Zhao, Lei Zheng and Caihao Hong for their helpful assistance with the calibration experiments.

References and links

1. Z. Chang, A. Rundquist, J. Zhou, M. M. Murnane, H. C. Kapteyn, X. Liu, B. Shan, J. Liu, L. Niu, M. Gong, and X. Zhang, “Demonstration of a sub-picosecond x-ray streakcamera,” Appl. Phys. Lett. 69(1), 133 (1996). [CrossRef]  

2. J. Y. Liu, J. Wang, B. Shan, C. Wang, and Z. H. Chang, “An accumulative x-ray streak camera with sub-600-fs temporal resolution and 50-fs timing jitter,” Appl. Phys. Lett. 82(20), 3553 (2003). [CrossRef]  

3. J. Feng, H. J. Shin, J. R. Nasiatka, W. Wan, A. T. Young, G. Huang, A. Comin, J. Byrd, and H. A. Padmore, “An x-ray streak camera with high spatio-temporal resolution,” Appl. Phys. Lett. 91(13), 134102 (2007). [CrossRef]  

4. O. A. Hurricane, D. A. Callahan, D. T. Casey, P. M. Celliers, C. Cerjan, E. L. Dewald, T. R. Dittrich, T. Döppner, D. E. Hinkel, L. F. Berzak Hopkins, J. L. Kline, S. Le Pape, T. Ma, A. G. MacPhee, J. L. Milovich, A. Pak, H.-S. Park, P. K. Patel, B. A. Remington, J. D. Salmonson, P. T. Springer, and R. Tommasini, “Fuel gain exceeding unity in an inertially confined fusion implosion,” Nature 506(7488), 343–348 (2014). [CrossRef]   [PubMed]  

5. J. D. Lindl and E. I. Moses, “Special Topic: Plans for the National Ignition Campaign (NIC) on the National Ignition Facility (NIF): On the threshold of initiating ignition experiments,” Phys. Plasmas 18(5), 050901 (2011). [CrossRef]  

6. J. Lindl, O. Landen, J. Edwards, E. Moses, and N. I. C. Team, “Review of the National Ignition Campaign 2009-2012,” Phys. Plasmas 21(2), 020501 (2014). [CrossRef]  

7. E. Loomis, F. Doss, K. Flippo, and J. Fincke, “Measurements of continuous mix evolution in a high energy density shear ow,” Phys. Plasmas 21(4), 044508 (2014). [CrossRef]  

8. P. W. Wachulak, A. Bartnik, R. Jarocki, T. Fok, Ł. Węgrzyński, J. Kostecki, M. Szczurek, J. Jabczyński, and H. Fiedorowicz, “Generation and characterization of plasma channels in gas puff targets using soft X-ray radiography technique,” Phys. Plasmas 21(10), 103106 (2014). [CrossRef]  

9. M. Eichberger, N. Erasmus, K. Haupt, G. Kassier, A. von Flotow, J. Demsar, and H. Schwoerer, “Femtosecond streaking of electron diffraction patterns to study structural dynamics in crystalline matter,” Appl. Phys. Lett. 102(12), 121106 (2013). [CrossRef]  

10. Y. Minami, Y. Hayashi, J. Takeda, and I. Katayama, “Single-shot measurement of a terahertz electric-field waveform using a re ective echelon mirror,” Appl. Phys. Lett. 103(5), 051103 (2013). [CrossRef]  

11. J. Andersson, P. Ni, and A. Anders, “Spectroscopic imaging of self-organization in high power impulse magnetron sputtering plasmas,” Appl. Phys. Lett. 103(5), 054104 (2013). [CrossRef]  

12. J. R. Kimbrough, P. M. Bell, G. B. Christianson, F. D. Lee, D. H. Kalantar, T. S. Perry, N. R. Sewall, and A. J. Wootton, “National Ignition Facility core x-ray streak camera,” Rev. Sci. Instrum. 72(1), 748 (2001). [CrossRef]  

13. O. V. Gotchev, P. A. Jaanimagi, J. P. Knauer, F. J. Marshall, D. D. Meyerhofer, N. L. Bassett, and J. B. Oliver, “High-throughput, high-resolution KirkpatrickBaez microscope for advanced streaked imaging of ICF experiments on OMEGA,” Rev. Sci. Instrum. 74(3), 2178 (2003). [CrossRef]  

14. J. F. Wu, W. Y. Miao, L. F. Wang, Y. T. Yuan, Z. R. Cao, W. H. Ye, Z. F. Fan, B. Deng, W. D. Zheng, M. Wang, W. B. Pei, S. P. Zhu, S. E. Jiang, S. Y. Liu, Y. K. Ding, W. Y. Zhang, and X. T. He, “Indirect-drive ablative Rayleigh-Taylor growth experiments on the Shenguang-II laser facility,” Phys. Plasmas 21(4), 042707 (2014). [CrossRef]  

15. Y. Pu, T. Huang, M. Wei, Q. Tang, Z. Song, J. Yang, S. Liu, S. Jiang, and Y. Ding, “Spectroscopic studies of shell mix in directly driven implosion on SGIII prototype laser facility,” Phys. Plasmas 21(12), 122707 (2014). [CrossRef]  

16. H. Shiraga, S. Fujioka, P. A. Jaanimagi, C. Stoeckl, R. B. Stephens, H. Nagatomo, K. A. Tanaka, R. Kodama, and H. Azechi, “Multi-imaging x-ray streak camera for ultrahigh-speed two-dimensional x-ray imaging of imploded core plasmas (invited),” Rev. Sci. Instrum. 75(10), 3921–3925 (2004). [CrossRef]  

17. M. C. Jackson, R. D. Long, D. Lee, and N. J. Freeman, “Development of X-ray streak camera electronics at AWRE,” Laser Part. Beams 4(01), 145 (1986). [CrossRef]  

18. C. D. Bentley and A. C. Simmons, “Spectral response calibrations of x-ray diode photo-cathodes in the 50-5900 eV photon energy region,” Rev. Sci. Instrum. 72(1), 1202 (2001). [CrossRef]  

19. K. M. Campbell, F. A. Weber, E. L. Dewald, S. H. Glenzer, O. L. Landen, R. E. Turner, and P. A. Waide, “Omega Dante soft x-ray power diagnostic component calibration at the National Synchrotron Light Source,” Rev. Sci. Instrum. 75(10), 3768–3771 (2004). [CrossRef]  

20. B. L. Henke, A. Smith, and D. T. Attwood, “0.1-10-keV x-ray-induced electron emissions from solids-Models and secondary electron measurements,” J. Appl. Phys. 48(5), 1852 (1977). [CrossRef]  

21. B. L. Henke, J. P. Knauer, and K. Premaratne, “The characterization of x-ray photocathodes in the 0.1-10-keV photon energy region,” J. Appl. Phys. 52(3), 1509–1520 (1981). [CrossRef]  

22. G. L. Stradling, H. Medecki, R. L. Kauffman, D. T. Attwood, and B. L. Henke, “Relative responses of CsI and Au photocathodes to 70-psec, 500-eV x-ray pulses,” Appl. Phys. Lett. 37(9), 782 (1980). [CrossRef]  

23. Z. Pan, K. Jensen, and P. O’Shea, “Modeling the quantum efficiency of controlled porosity dispenser photocathodes,” Appl. Phys. Lett. 100(3), 034102 (2012). [CrossRef]  

24. S. Matsui, K. Mori, K. Saigo, T. Shiokawa, K. Toyoda, and S. Namba, “Lithographic approach for 100 nm fabrication by focused ion beam,” J. Vac. Sci. Technol. B 4(4), 845 (1986). [CrossRef]  

25. S. J. Spector, C. J. Jacobsen, and D. M. Tennant, “Process optimization for production of sub-20nm soft X-ray zone plates,” J. Vac. Sci. Technol. B 15(6), 2872 (1997). [CrossRef]  

26. E. H. Anderson, D. L. Olynick, B. Harteneck, E. Veklerov, G. Denbeaux, W. L. Chao, A. Lucero, L. Johnson, and D. Attwood, “Nanofabrication and diffractive optics for high-resolution x-ray applications,” J. Vac. Sci. Technol. B 18(6), 2970 (2000). [CrossRef]  

27. C. Xie, X. Zhu, H. Li, L. Shi, J. Niu, Y. Hua, and L. Shi, “Fabrication of x-ray diffractive optical elements for laser fusion applications,” Opt. Eng. 52(3), 033402 (2013). [CrossRef]  

28. L. Kuang, L. Cao, X. Zhu, S. Wu, Z. Wang, C. Wang, S. Liu, S. Jiang, J. Yang, Y. Ding, C. Xie, and J. Zheng, “Quasi-sinusoidal single-order diffraction transmission grating used in x-ray spectroscopy,” Opt. Lett. 36(20), 3954–3956 (2011). [CrossRef]   [PubMed]  

29. H. P. Zang, C. K. Wang, Y. L. Gao, W. M. Zhou, L. Y. Kuang, L. Wei, W. Fan, W. H. Zhang, Z. Q. Zhao, L. F. Cao, Y. Q. Gu, B. H. Zhang, G. Jiang, X. L. Zhu, C. Q. Xie, Y. D. Zhao, and M. Q. Cui, “Elimination of higher-order diffraction using zigzag transmission grating in soft x-ray region,” Appl. Phys. Lett. 100(11), 111904 (2012). [CrossRef]  

30. H. F. Robey, P. M. Celliers, J. L. Kline, A. J. Mackinnon, T. R. Boehly, O. L. Landen, J. H. Eggert, D. Hicks, S. Le Pape, D. R. Farley, M. W. Bowers, K. G. Krauter, D. H. Munro, O. S. Jones, J. L. Milovich, D. Clark, B. K. Spears, R. P. Town, S. W. Haan, S. Dixit, M. B. Schneider, E. L. Dewald, K. Widmann, J. D. Moody, T. D. Döppner, H. B. Radousky, A. Nikroo, J. J. Kroll, A. V. Hamza, J. B. Horner, S. D. Bhandarkar, E. Dzenitis, E. Alger, E. Giraldez, C. Castro, K. Moreno, C. Haynam, K. N. LaFortune, C. Widmayer, M. Shaw, K. Jancaitis, T. Parham, D. M. Holunga, C. F. Walters, B. Haid, T. Malsbury, D. Trummer, K. R. Coffee, B. Burr, L. V. Berzins, C. Choate, S. J. Brereton, S. Azevedo, H. Chandrasekaran, S. Glenzer, J. A. Caggiano, J. P. Knauer, J. A. Frenje, D. T. Casey, M. G. Johnson, F. H. Séguin, B. K. Young, M. J. Edwards, B. M. Van Wonterghem, J. Kilkenny, B. J. MacGowan, J. Atherton, J. D. Lindl, D. D. Meyerhofer, and E. Moses, “Precision Shock Tuning on the National Ignition Facility,” Phys. Rev. Lett. 108(21), 215004 (2012). [CrossRef]   [PubMed]  

31. Z. Li, X. Jiang, S. Liu, T. Huang, J. Zheng, J. Yang, S. Li, L. Guo, X. Zhao, H. Du, T. Song, R. Yi, Y. Liu, S. Jiang, and Y. Ding, “A novel flat-response x-ray detector in the photon energy range of 0.1-4 keV,” Rev. Sci. Instrum. 81(7), 073504 (2010). [CrossRef]   [PubMed]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (3)

Fig. 1
Fig. 1 Schematic diagram of (a) the designed at-response photocathode, (b) the structure-improved photocathode, (c) the side-view profile of the cross section of the structure-improved photocathode and (d) the front view of the thicker gold foil which has uniformly distributed pin-holes.
Fig. 2
Fig. 2 Schematic diagram of the calibration-experiment setup at the x-ray beam-lines at the Beijing Synchrotron Radiation Facility.
Fig. 3
Fig. 3 Calculated and calibrated spectral responses of the photocathodes in the photon-energy range of 0.1-5 keV.

Equations (3)

Equations on this page are rendered with MathJax. Learn more.

S(E)ρu(E) λ s [(1a) e t 1 / λ x (1 e t 1 / λ s )+a e ( t 1 + t 2 )/ λ x (1 e ( t 1 + t 2 )/ λ s )]
σ= E 1 E 2 (S S ¯ ) 2 dx ( E 2 E 1 ) S ¯ 2
R(E)= I 1 (E) R sta (E) I 0 (E) .
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.